Surgical assistant manipulator with diagonal joints and multi-stage telescopic screws for laparoscopic solo surgery.
Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Surgical assistant manipulator with diagonal joints and multi-stage telescopic screws for laparoscopic solo surgery.International journal of computer assisted radiology and surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 1 country.
Funding
Abstract
purposeA surgeon in a sterilized area can perform robotically assisted laparoscopic solo surgery while controlling a laparoscope-holding robot for view stabilization and a forceps robot for pulling organs. At present, no locally operated surgical assistant manipulator with a mechanical remote center of motion (RCM) is available to operate within a small space while providing a wide range of movement. The present study describes a new locally operated detachable end-effector manipulator (LODEM) with diagonal joints and multi-stage telescopic screws.
methodsA forceps manipulator attached to commercial surgical forceps was developed. This manipulator uses RCM diagonal joints for the yaw and pitch axes, providing an intuitive pivot point and free rotation, and telescopic nested screws with multiple sliders clamp the commercial forceps for the axis of insertion. The manipulator placed above the abdominal wall using a fixed arm connected to a bed rail is motor controlled by a handheld interface with button switches for precise traction and is controlled manually for easy rough positioning.
resultsPositional accuracy at the tip with a load of 5 N was under 0.5 mm. Mechanical deflection was under 2.1 mm. The manually controlled force was under 4.4 N. Successful simulated laparoscopic cholecystectomy using the prototype manipulator to handle the target and maintain stability was performed on a surgically realistic gallbladder model.
conclusionsA LODEM with diagonal joints and multi-stage telescopic screws was developed to facilitate minimally invasive, robotically assisted laparoscopic solo surgery by a surgeon working near the patient. This electric motor-controlled laparoscopic instrument holder by the surgeon in the surgical field could be used for such applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.