ArticleQuantitative imaging in medicine and surgery2022
The synthesis of high-energy CT images from low-energy CT images using an improved cycle generative adversarial network.
Article in Quantitative imaging in medicine and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Synthetic Data Generation via Generative Adversarial Networks in Healthcare: A Systematic Review of Image- and Signal-Based Studies.IEEE open journal of engineering in medicine and biology · 2025Article
- The value of dual-energy CT virtual monoenergetic imaging and metal-artifacts reduction system after metal plate correction of congenital funnel chest in child: a single center retrospective study.Frontiers in pediatrics · 2025Article
- Transferring U-Net between low-dose CT denoising tasks: a validation study with varied spatial resolutions.Quantitative imaging in medicine and surgery · 2024Article
- A two-stage deep-learning framework for CT denoising based on a clinically structure-unaligned paired data set.Quantitative imaging in medicine and surgery · 2024Article
- Synthetic high-energy computed tomography image via a Wasserstein generative adversarial network with the convolutional block attention module.Quantitative imaging in medicine and surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe dose of radiation a patient receives when undergoing dual-energy computed tomography (CT) is of significant concern to the medical community, and balancing the tradeoffs between the level of radiation used and the quality of CT images is challenging. This paper proposes a method of synthesizing high-energy CT (HECT) images from low-energy CT (LECT) images using a neural network that achieves an alternative to HECT scanning by employing an LECT scan, which greatly reduces the radiation dose a patient receives.
methodsIn the training phase, the proposed structure cyclically generates HECT and LECT images to improve the accuracy of extracting edge and texture features. Specifically, we combine multiple connection methods with channel attention (CA) and pixel attention (PA) mechanisms to improve the network's mapping ability of image features. In the prediction phase, we use a model consisting of only the network component that synthesizes HECT images from LECT images.
resultsOur proposed method was conducted on clinical hip CT image data sets from Guizhou Provincial People's Hospital. In a comparison with other available methods [a generative adversarial network (GAN), a residual encoder-to-decoder network with a visual geometry group (VGG) pretrained model (RED-VGG), a Wasserstein GAN (WGAN), and CycleGAN] in terms of metrics of peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), normalized mean square error (NMSE), and a visual effect evaluation, the proposed method was found to perform better on each of these evaluation criteria. Compared with the results produced by CycleGAN, the proposed method improved the PSNR by 2.44%, the SSIM by 1.71%, and the NMSE by 15.2%. Furthermore, the differences in the statistical indicators are statistically significant, proving the strength of the proposed method.
conclusionsThe proposed method synthesizes high-energy CT images from low-energy CT images, which significantly reduces both the cost of treatment and the radiation dose received by patients. Based on both image quality score metrics and visual effects comparisons, the results of the proposed method are superior to those obtained by other methods.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.