Evidence map›Paper›PMID 34992862›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology2021

Impact of rotational errors of whole pelvis on the dose of prostate-based image-guided radiotherapy to pelvic lymph nodes and small bowel in high-risk prostate cancer.

Hiroki Katayama, Shigeo Takahashi, Takuya Kobata, Akihiro Oishi, Toru Shibata

Open access · diamondAbstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Assessment of dosimetric impact of interfractional 6D setup error in tongue cancer treated with IMRT and VMAT using daily kV-CBCT.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2023
    Article
  2. Surface-guided radiotherapy improves rotational accuracy in gynecological cancer patients.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Hiroki KatayamaDepartment of Clinical Radiology, Kagawa University Hospital, Kagawa, Japan.
Shigeo TakahashiDepartment of Radiation Oncology, Kagawa University Hospital, Kagawa, Japan.
Takuya KobataDepartment of Clinical Radiology, Kagawa University Hospital, Kagawa, Japan.
Akihiro OishiDepartment of Clinical Radiology, Kagawa University Hospital, Kagawa, Japan.
Toru ShibataDepartment of Radiation Oncology, Kagawa University Hospital, Kagawa, Japan.
Kagawa University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe target volume increases when the prostate and pelvic lymph nodes (PLNs) are combined, and the fiducial markers (FMs) are placed at the edge of the irradiation field. Thus, the position of FMs may be changed by the rotational errors (REs) of "whole pelvis". The aim of this study was to examine the impact of REs of "whole pelvis" on the dose of FMs-based image-guided radiotherapy to the PLNs and the small bowel in prostate cancer including the PLNs. MATERIALS AND

methodsWe retrospectively evaluated 10 patients who underwent prostate cancer radiotherapy involving the PLNs. The position of FMs was calculated from the radiographs obtained before and after the 6D correction of pelvic REs. We simulated the delivery dose considering the daily pelvic REs and calculated the difference from the planned dose in the D

resultThe position of FMs strongly correlated with the pelvic REs in the pitch direction (r = 0.7788). However, the mean delivered doses to PLNs for 10 patients were not significantly different from the planned doses (p = 0.625). Although the D

conclusionThe dosimetric effect of pelvic REs on the dose to PLNs and the small bowel was negligible during the treatment course.

Indexed as

fiducial markerimage-guided radiotherapy (IGRT)pelvic lymph nodesprostate cancerrotational errors

Identifiers

PMID34992862
PMCPMC8726453
OpenAlexW3207675341

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked