Objective Content Validation of the Hemodynamic and Technical Parameters of the Orpheus

Bruce E Searles, Edward M Darling, Jeffrey B Riley, Jacob McNinch, Erik Rufa, Jason R Wiles

Open access · greenAbstract read
In one paragraph

Article in The journal of extra-corporeal technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Leadership and Mentoring.The journal of extra-corporeal technology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Bruce E SearlesDepartment of Cardiovascular Perfusion, College of Health Professions, SUNY Upstate Medical University, Syracuse, New York.
Edward M DarlingDepartment of Cardiovascular Perfusion, College of Health Professions, SUNY Upstate Medical University, Syracuse, New York.
Jeffrey B RileyDepartment of Cardiovascular Perfusion, College of Health Professions, SUNY Upstate Medical University, Syracuse, New York.
Jacob McNinchDepartment of Cardiovascular Perfusion, Intermountain Medical Center, Syracuse, New York.
Erik RufaSimulation Center, College of Medicine, SUNY Upstate Medical University, Syracuse, New York; and.
Jason R WilesDepartments of Biology and Science Teaching, College of Arts and Science, Syracuse University, Syracuse, New York.
SUNY Upstate Medical University · USSyracuse University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The utilization of simulators for training is increasing in the professions associated with cardiac surgery. Before applying these simulators to high-stakes assessment, the simulator's output data must be validated. The aim of this study is to validate a Cardiopulmonary Bypass (CPB) simulator by comparing the simulated hemodynamic and technical outputs to published clinical norms. Three Orpheus™ CPB simulators were studied and compared to a published reference of physiologic and technical metrics that are managed during clinical CPB procedures. The limits of the simulators user modifiable variables were interrogated across their full range and the results were plotted against the published clinical norms. The data generated with the simulator conforms to validated clinical parameters for patients between 50 and 110 kg. For the pre- and post-CPB periods, the independent variables of central venous pressure (CVP), heart rate (HR), contractility, and systemic vascular resistance (SVR) must be operated between the limits of 7 and 12 mmHg, 65 and 110 beats/min, 28% and 65%, and 6 and 32 units respectively. During full CPB the arterial pump flows should be maintained between 3.5 and 5.5 LPM and SVR between 18 and 38 units. Validated technical parameters during cardioplegia delivery are expected at solution flow rates between 250 and 400 mL/min and 100 and 225 mL/min for antegrade and retrograde delivery routes, respectively. We have identified the limits for user-modifiable settings that produce data conforming to the physiologic and technical parameter limits reported in the peer reviewed literature. These results can inform the development of simulation scenarios used for high stakes assessments of personnel, equipment, and technical protocols.

Indexed as

Cardiac Surgical ProceduresCardiopulmonary BypassHeart Arrest, InducedHemodynamicsHumanscardiopulmonary bypasseducationsimulationvalidity.

Identifiers

PMID34992316
PMCPMC8717731
OpenAlexW4206487816

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.