ArticleSurgical endoscopy2022
Accuracy in optical diagnosis for polyps between 5 and 15 mm and its implications on surveillance. A prospective, multicenter study. (POPS study).
Article in Surgical endoscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04232176 (Precision of Optical Diagnosis in Polyps Between 5-15 mm and Its Implications on Surveillance. A Prospective, Multicenter Study.), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Precision of Optical Diagnosis in Polyps Between 5-15 mm and Its Implications on Surveillance. A Prospective, Multicenter Study.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND AND
aimsPolyps histology and diameter up to 1 cm determine whether a patient needs a colonoscopy after 3 years or less, or far ahead. Endoscopists' and pathologists' size estimations can be imprecise. Our aim was to assess endoscopist ability to correctly recommend surveillance colonoscopies for patients with polyps around the 10 mm threshold, based on its endoscopic sizing and optical diagnosis by NBI.
methodsNBI-assisted diagnosis and endoscopist estimation of polyp size were compared with reference standard, considering this as the post resection polyp measurements by the nurse assistant and the pathologic results, in a prospective, multicenter, real life study, that recruited adults undergoing colonoscopy in five hospitals. By comparing the endoscopic and pathologist size estimation, with polyps' measurement after resection, and optical and histological diagnoses in patients with polyps between 5 and 15 mm, sensitivity was assessed at the patient level by means of two characteristics: the presence of adenoma, and the surveillance interval. Surveillance intervals were established by the endoscopist, based on optical diagnosis, and by another gastroenterologist, grounded on the pathologic report. Determinants of accuracy were explored at the polyp level.
results532 polyps were resected in 451 patients. Size estimation was more precise for the endoscopist. Endoscopist sensitivity for the presence of adenoma or carcinoma was 98.7%. Considering the presence of high-grade dysplasia or cancer, sensitivity was 82.6% for the endoscopic optical diagnosis. Sensitivity for a correct 3-year surveillance interval was 91.5%, specificity 82.3%, with a PPV of 93.2% and NPV of 78.5% for the endoscopist. 6.51% of patients would have had their follow-up colonoscopy delayed, whereas 22 (4.8%) would have it been performed earlier, had endoscopist recommendations been followed.
conclusionOur study observes that NBI optical diagnosis can be recommended in routine practice to establish surveillance intervals for polyps between 5 and 15 mm. CLINICAL TRIALS REGISTRATION NUMBER: NCT04232176.
Indexed as
Identifiers
34988735What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.