Evidence map›Paper›PMID 34988735›Full record

ArticleSurgical endoscopy2022

Accuracy in optical diagnosis for polyps between 5 and 15 mm and its implications on surveillance. A prospective, multicenter study. (POPS study).

Eduardo Redondo-Cerezo, Clara Heredia-Carrasco, Carlos Alegría-Motte, Antonio Caballero-Mateos, Francisco Vadillo-Calles, Eva Julissa Ortega-Suazo, Virgilio Martos-Ruiz, Jose Luis Ariza-Fernández, Elisabet López-González, Juan Gabriel Martínez-Cara and 5 more

Registry-linked trialAbstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04232176 (Precision of Optical Diagnosis in Polyps Between 5-15 mm and Its Implications on Surveillance. A Prospective, Multicenter Study.), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04232176 completednot on this map

Precision of Optical Diagnosis in Polyps Between 5-15 mm and Its Implications on Surveillance. A Prospective, Multicenter Study.

TypeobservationalSponsorUniversity Hospital Virgen de las NievesRan2019 to 2022Enrolled545ConditionsColonic Polyps, Colon Neoplasms, Colon Cancer, Serrated Adenoma
3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Eduardo Redondo-CerezoEndoscopy Unit, Department of Gastroenterology and Hepatology, "Virgen de Las Nieves" University Hospital, Avenida de las Fuerzas Armadas 2, 18014, Granada, Spain. eredondoc@gmail.com.ORCID http://orcid.org/0000-0002-5932-8540
Clara Heredia-CarrascoEndoscopy Unit, Department of Gastroenterology and Hepatology, "Virgen de Las Nieves" University Hospital, Avenida de las Fuerzas Armadas 2, 18014, Granada, Spain.
Carlos Alegría-MotteInternal Medicine Service, Hospital Comarcal "Santa Ana", Motril, Spain.
Antonio Caballero-MateosInternal Medicine Service, Hospital Comarcal "Santa Ana", Motril, Spain.
Francisco Vadillo-CallesInternal Medicine Service, Hospital Comarcal "Virgen del Puerto", Plasencia, Spain.
Eva Julissa Ortega-SuazoEndoscopy Unit, Department of Gastroenterology and Hepatology, "Virgen de Las Nieves" University Hospital, Avenida de las Fuerzas Armadas 2, 18014, Granada, Spain.
Virgilio Martos-RuizInternal Medicine Service, Hospital Comarcal "Santa Ana", Motril, Spain.
Jose Luis Ariza-FernándezGastroenterology Service, Hospital Comarcal de Poniente, El Ejido, Spain.
Elisabet López-GonzálezInternal Medicine Service, Hospital Comarcal "Vega Baja", Orihuela, Spain.
Juan Gabriel Martínez-CaraEndoscopy Unit, Department of Gastroenterology and Hepatology, "Virgen de Las Nieves" University Hospital, Avenida de las Fuerzas Armadas 2, 18014, Granada, Spain.
Francisco Valverde-LopezEndoscopy Unit, Department of Gastroenterology and Hepatology, "Virgen de Las Nieves" University Hospital, Avenida de las Fuerzas Armadas 2, 18014, Granada, Spain.
Mercedes López de HierroEndoscopy Unit, Department of Gastroenterology and Hepatology, "Virgen de Las Nieves" University Hospital, Avenida de las Fuerzas Armadas 2, 18014, Granada, Spain.
Damián Sánchez-CapillaEndoscopy Unit, Department of Gastroenterology and Hepatology, "Virgen de Las Nieves" University Hospital, Avenida de las Fuerzas Armadas 2, 18014, Granada, Spain.
Javier Luis López-HidalgoPathology Department, "Virgen de Las Nieves" University Hospital, Granada, Spain.
Rita Jimenez-RosalesEndoscopy Unit, Department of Gastroenterology and Hepatology, "Virgen de Las Nieves" University Hospital, Avenida de las Fuerzas Armadas 2, 18014, Granada, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimsPolyps histology and diameter up to 1 cm determine whether a patient needs a colonoscopy after 3 years or less, or far ahead. Endoscopists' and pathologists' size estimations can be imprecise. Our aim was to assess endoscopist ability to correctly recommend surveillance colonoscopies for patients with polyps around the 10 mm threshold, based on its endoscopic sizing and optical diagnosis by NBI.

methodsNBI-assisted diagnosis and endoscopist estimation of polyp size were compared with reference standard, considering this as the post resection polyp measurements by the nurse assistant and the pathologic results, in a prospective, multicenter, real life study, that recruited adults undergoing colonoscopy in five hospitals. By comparing the endoscopic and pathologist size estimation, with polyps' measurement after resection, and optical and histological diagnoses in patients with polyps between 5 and 15 mm, sensitivity was assessed at the patient level by means of two characteristics: the presence of adenoma, and the surveillance interval. Surveillance intervals were established by the endoscopist, based on optical diagnosis, and by another gastroenterologist, grounded on the pathologic report. Determinants of accuracy were explored at the polyp level.

results532 polyps were resected in 451 patients. Size estimation was more precise for the endoscopist. Endoscopist sensitivity for the presence of adenoma or carcinoma was 98.7%. Considering the presence of high-grade dysplasia or cancer, sensitivity was 82.6% for the endoscopic optical diagnosis. Sensitivity for a correct 3-year surveillance interval was 91.5%, specificity 82.3%, with a PPV of 93.2% and NPV of 78.5% for the endoscopist. 6.51% of patients would have had their follow-up colonoscopy delayed, whereas 22 (4.8%) would have it been performed earlier, had endoscopist recommendations been followed.

conclusionOur study observes that NBI optical diagnosis can be recommended in routine practice to establish surveillance intervals for polyps between 5 and 15 mm. CLINICAL TRIALS REGISTRATION NUMBER: NCT04232176.

Indexed as

AdenomaColonic PolypsColorectal NeoplasmsAdultColonoscopyHumansNarrow Band ImagingPredictive Value of TestsProspective StudiesAdenomatous polypsColon neoplasmsColonoscopyNBISmall polyps

Identifiers

What OpenQuestion holds