ArticleData in brief2021
Safety and biocompatibility of a bionic eye: Imaging, intraocular pressure, and histology data.
Article in Data in brief, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
21 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The data presented here are related and supplementary data to the research article "Implantation and long-term assessment of the stability and biocompatibility of a novel 98 channel suprachoroidal visual prosthesis in sheep" [1]. In Eggenberger et al., nine sheep of the Suffolk (N=2) and Dorper (N=7) breeds were implanted in the left eye with an electrically inactive, suprachoroidal retinal stimulator (Bionic Eye) for durations of up to 100 days. The surgical safety, implant stability and device biocompatibility were assessed. Intraocular pressure measurements, indirect and infrared ophthalmoscopy and optical coherence tomography were performed at fixed time points to evaluate the clinical effects of the surgery and device implantation. Post-mortem eye tissue collection and histology was performed to measure the effects of the intervention at the cellular level. The data, including a comprehensive collection of fundus, infrared, optical coherence tomography and histology images can be used as a reference for comparison with other research, for example, active retinal stimulators. Furthermore, these data can be used to evaluate the suitability of the sheep model, in particular Dorper sheep, for future research.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.