ArticleBMC musculoskeletal disorders2022
Volar versus combined dorsal and volar plate fixation of complex intraarticular distal radius fractures with small dorsoulnar fragment - a biomechanical study.
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 12 citations in OpenAlex.
- Bone substitute in distal radius osteotomy: a prospective randomized double-blinded study on micromotion and outcomes in 42 patients up to one year.Archives of orthopaedic and trauma surgery · 2025Trial
- Early return to cycling after dorsal spanning plate fixation for distal radius fracture in a KEIRIN athlete: a case report.Annals of medicine and surgery (2012) · 2026Article
- Dual Plating and Dorsal Bridge Plating for Comminuted Distal Radius Fractures: A Systematic Review.Journal of clinical medicine · 2026Review
- Dorsal bridge plating, volar plating, or both? A retrospective analysis of clinical and radiographic outcomes of intraarticular distal radius fracture fixation techniques.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Article
- Biomechanical comparison of radiopalmar double plating with conventional palmar plating in comminuted distal radius fractures.Archives of orthopaedic and trauma surgery · 2026Article
- Radiographic and functional outcomes of dorsal-assisted volar plate fixation in comminuted intra-articular distal radius fractures: a prospective study.International journal of burns and trauma · 2026Article
- Displaced dorsal rim fragment in distal radius fracture: what is the size threshold for compromise?Archives of orthopaedic and trauma surgery · 2024Article
- Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report.Journal of orthopaedic case reports · 2024Article
- Management of complex wrist fractures with volar and dorsal locked (double-locked) K-lock.OTA international : the open access journal of orthopaedic trauma · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Complex intraarticular distal radius fractures (DRFs), commonly managed with volar locking plates, are challenging. Combined volar and dorsal plating is frequently applied for treatment, however, biomechanical investigations are scant. The aim of this biomechanical study was to investigate volar plating versus double plating in DRFs with different degrees of lunate facet comminution.Thirty artificial radii with simulated AO/OTA 23-C2.1 and C3.1 DRFs, including dorsal defect and lunate facet comminution, were assigned to 3 groups: Group 1 with two equally-sized lunate facet fragments; Group 2 with small dorsal and large volar fragment; Group 3 with three equally-sized fragments. The specimens underwent volar and double locked plating and non-destructive ramped loading in 0° neutral position, 40° flexion and 40° extension.In each tested position, stiffness: (1) did not significantly differ among groups with same fixation method (p ≥ 0.15); (2) increased significantly after supplemental dorsal plating in Group 2 and Group 3 (p ≤ 0.02).Interfragmentary displacements between styloid process and lunate facet in neutral position were below 0.5 mm, being not significantly different among groups and plating techniques (p ≥ 0.63).Following volar plating, angular displacement of the lunate facet to radius shaft was significantly lower in Group 1 versus both Group 2 and Group 3 (p < 0.01). It decreased significantly after supplemental dorsal plating in Group 2 and Group 3 (p < 0.01), but not in Group 1 (p ≥ 0.13), and did not differ significantly among the three groups after double plating (p ≥ 0.74).Comminution of the lunate facet within its dorsal third significantly affected the biomechanical outcomes related to complex intraarticular DRFs treated with volar and double locked plates.Double plating demonstrates superior stability versus volar plating only for lunate facet comminution within its dorsal third. In contrast, volar plating could achieve stability comparable with double plating when the dorsal third of the lunate facet is not separated by the fracture pattern. Both fixation methods indicated achievable absolute stability between the articular fragments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.