Evidence map›Paper›PMID 34985179›Full record

ArticleJournal of applied clinical medical physics2022

Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study.

Haenghwa Lee, Jeong-Mee Park, Kwang Hyeon Kim, Dong-Hoon Lee, Moon-Jun Sohn

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Haenghwa LeeDepartment of Neurosurgery, Neuroscience, & Radiosurgery Hybrid Research Center, Inje University Ilsan Paik Hospital, College of Medicine, Goyang, Republic of Korea.
Jeong-Mee ParkDepartment of Neurosurgery, Neuroscience, & Radiosurgery Hybrid Research Center, Inje University Ilsan Paik Hospital, College of Medicine, Goyang, Republic of Korea.
Kwang Hyeon KimDepartment of Neurosurgery, Neuroscience, & Radiosurgery Hybrid Research Center, Inje University Ilsan Paik Hospital, College of Medicine, Goyang, Republic of Korea.
Dong-Hoon LeeDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Moon-Jun SohnDepartment of Neurosurgery, Neuroscience, & Radiosurgery Hybrid Research Center, Inje University Ilsan Paik Hospital, College of Medicine, Goyang, Republic of Korea.
Inje University Ilsan Paik Hospital · KRMemorial Sloan Kettering Cancer Center · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748the Ministry of Education NRF-2020R1I1A3073930
6 · The paper itself

Abstract

purposeTo evaluate a feasibility of normal distribution transform (NDT) algorithm compared with the iterative closest point (ICP) method as a useful surface registration in stereotactic body radiotherapy (SBRT)/stereotactic radiosurgery (SRS).

methodsPoint cloud images using the 3D triangulation technology were obtained from a depth camera-based optical imaging (OSI) system equipped in a radiosurgery room. Two surface registration algorithms, NDT and ICP, were used to measure and compare the discrepancy values between the reference and the current surfaces during the positioning of the patient. The performance evaluation was investigated by calculating the registration error and root-mean-square (RMS) values for the surface model, reposition, and target accuracy, which were analyzed statistically using a paired t-test.

resultsFor surface model accuracy, the average of the registration error and RMS values were measured as 3.56 ± 2.20 mm and 6.98 ± 1.89 mm for ICP method, and 1.76 ± 1.32 mm and 3.58 ± 1.30 mm for NDT method (p < 0.05). For reposition accuracy, the average registration error and RMS values were calculated as 1.41 ± 0.98 mm and 2.53 ± 1.64 mm using ICP method, and 0.92 ± 0.61 mm and 1.75 ± 0.80 mm using NDT method (p = 0.005). The overall target accuracy using the NDT method reduced the average of the reposition error and overall RMS value by 0.71 and 1.32 mm, respectively, compared to the ICP method (p = 0.03).

conclusionsWe found that the surface registration algorithm based on NDT method provides more reliable accuracy in the values of surface model, reposition, and target accuracies than the classic ICP method. The NDT method in OSI systems offers reasonable accuracy in SBRT/SRS.

Indexed as

RadiosurgeryAlgorithmsHumansNormal DistributionPhantoms, ImagingNormal distribution transform algorithmoptical surface imagingsurface registration algorithm

Identifiers

PMID34985179
PMCPMC8906233
OpenAlexW4206783835

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.