ArticleMagnetic resonance in medicine2022
On the fat saturation effect in quantitative ultrashort TE MR imaging.
Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 11 citations in OpenAlex.
- Clinical applications of UTE-T2* in knee MRI.Skeletal radiology · 2026Review
- Data-Driven Characterization of Knee Structures Using Non-Negative Matrix Factorization of 3D Multi-Echo UTE MRI.NMR in biomedicine · 2026Article
- Fat-suppressed quantitative ultrashort echo time magnetization transfer (UTE-MT) imaging of the knee joint.Magma (New York, N.Y.) · 2026Article
- Significant age-related differences between lower leg muscles of older and younger female subjects detected by ultrashort echo time magnetization transfer modeling.NMR in biomedicine · 2024Article
- Rotator cuff muscle fibrosis can be assessed using ultrashort echo time magnetization transfer MRI with fat suppression.NMR in biomedicine · 2024Article
- Bi-Exponential 3D UTE-T1ρ Relaxation Mapping of Ex Vivo Human Knee Patellar Tendon at 3T.Bioengineering (Basel, Switzerland) · 2024Article
- Tendon evaluation with ultrashort Echo Time (UTE) MRI: A Systematic Review.Frontiers in musculoskeletal disorders · 2024Article
- Assessment of ultrashort echo time (UTE) TQuantitative imaging in medicine and surgery · 2023Article
- Robust Assessment of Macromolecular Fraction (MMF) in Muscle with Differing Fat Fraction Using Ultrashort Echo Time (UTE) Magnetization Transfer Modeling with Measured T1.Diagnostics (Basel, Switzerland) · 2023Article
- Ultrashort echo time magnetic resonance imaging of the osteochondral junction.NMR in biomedicine · 2023Review
- Articular Cartilage Assessment Using Ultrashort Echo Time MRI: A Review.Frontiers in endocrinology · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
Abstract
purposeTo investigate the effect of fat saturation (FatSat) on quantitative UTE imaging of variable knee tissues on a 3T scanner.
methodsThree quantitative UTE imaging techniques, including the UTE multi-echo sequence for
resultsFat was well-suppressed using all three UTE sequences when FatSat was deployed. For the small sample study, the quantification difference ratio (QDR) values of all the measured biomarkers ranged from 0.7% to 12.6%, whereas for the whole knee joint specimen study, the QDR values ranged from 0.2% to 12.0%. Except for T
conclusionThe UTE biomarkers showed good correlation and agreement with some slight differences between the scans with and without FatSat.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.