ArticleActa orthopaedica2022
Continuous periprosthetic bone loss but preserved stability for a collum femoris-preserving stem: follow-up of a prospective cohort study of 21 patients with dualenergy X-ray absorptiometry and radiostereometric analysis with minimum 8 years of follow-up.
Article in Acta orthopaedica, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.
- Comparing the Efficacy of Antiosteoporotic Drugs in Preventing Periprosthetic Bone Loss Following Total Hip Arthroplasty: A Systematic Review and Bayesian Network Meta-Analysis.Orthopaedic surgery · 2024Pooled it
- Periprosthetic bone mineral density, assessed using dual energy x-ray absorptiometry, following arthroplasty in patients with femoral neck fracture: 5-year outcomes of a randomized controlled trial.The Journal of international medical research · 2024Trial
- Short versus conventional straight stem in uncemented total hip arthroplasty: functional outcomes up to 5 years and survival up to 12 years: secondary results of a randomized controlled trial.Acta orthopaedica · 2024Trial
- Is Collum Femoris Preserving Stem (CFP) an Epiphyseal-Stabilized Prosthesis? A Long-Term Single-Center Series Follow Up of 705 Cases.Orthopaedic surgery · 2025Article
- Risk Factors of Aseptic Loosening After Total Hip Arthroplasty With Collum Femoris Preserving Stem: A Long-Term Follow-Up Study.Orthopaedic surgery · 2025Article
- Variations in bone mineral density after joint replacement: A systematic review examining different anatomical regions, fixation techniques and implant design.Journal of experimental orthopaedics · 2025Review
- Biomechanical Properties of Bionic Collum Femoris Preserving Hip Prosthesis: A Finite Element Analysis.Orthopaedic surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and purpose - We previously described a decrease in bone mineral density (BMD) in the calcar region 2 years after insertion of the collum femoris-preserving (CFP) stem, but the implants were stable. Now we have examined the long-term changes in periprosthetic BMD and stability of the CFP stem. Patients and methods - We conducted a minimum 8-year follow-up of 21 patients from our original investigation. We examined periprosthetic BMD by dual-energy X-ray absorptiometry (DEXA) and implant stability by radiostereometric analysis (RSA). Results - Between 2 and 8 years 1 stem was revised due to aseptic loosening. Between 2 and 8 years we found a 14% (95% confidence interval [CI] 9-19) reduction in BMD in Gruen zone 6 and 17% (CI 6-28) in Gruen zone 7. From baseline the reduction in BMD was 30% (CI 23-36) in Gruen zone 6, 39% (CI 31-47) in Gruen zone 7, and 19% (CI 14-23) in Gruen zone 2. Between 2 and 8 years, RSA (n = 17) showed a mean translation along the stem axis of 0.02mm (CI -0.02 to 0.06) and a mean rotation around the stem axis of 0.08° (CI -0.26 to 0.41). From baseline mean subsidence was 0.07 mm (CI -0.16 to 0.03) and mean rotation around the stem axis was 0.23° (CI -0.23 to 0.68) at 8 years. Interpretation - There was continuous loss of proximomedial BMD at 8 years while the CFP stem remained stable. Proximal periprosthetic bone loss cannot be prevented by this stem.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.