Evidence map›Paper›PMID 34983577›Full record

ArticleJournal of orthopaedic surgery and research2022

The proximal humeral locking plate positioning to the pectoralis major tendon in achieving the proper calcar screw location: a cadaveric study.

Nattha Kulkamthorn, Naruebade Rungrattanawilai, Thanakorn Tarunotai, Nantaphon Chuvetsereporn, Piyachat Chansela, Ong-Art Phruetthiphat

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Observational
  2. [Research progress on medial support augmentation techniques for proximal humeral fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nattha KulkamthornOrthopaedics Department, Phramongkutklao Hospital, 315 Ratchvidhi Road, Thung Phaya Thai, Ratchathewee, Bangkok, 10400, Thailand.
Naruebade RungrattanawilaiDepartment of Orthopaedic Surgery, Queen Sirikit Naval Hospital, Phlu Ta Luang, Thailand.
Thanakorn TarunotaiDepartment of Orthopaedic Surgery, Nopparatratchathani Hospital, Bangkok, Thailand.
Nantaphon ChuvetserepornDepartment of Orthopaedic Surgery, Faculty of Medicine, Burapha University, Saen Suk, Thailand.
Piyachat ChanselaDepartment of Anatomy, Phramongkutklao College of Medicine, Bangkok, Thailand.
Ong-Art PhruetthiphatOrthopaedics Department, Phramongkutklao Hospital, 315 Ratchvidhi Road, Thung Phaya Thai, Ratchathewee, Bangkok, 10400, Thailand. ophruetthiphat@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProximal humeral fracture is the third most common of osteoporotic fracture. Most surgical cases were treated by fixation with anatomical locking plate system. The calcar screw plays a role in medial support and improving varus stability. Proximal humerus fracture in elderly patients are commonly seen with greater tuberosity (GT) fracture. The GT fragment is sometimes difficult to use as an anatomic landmark for proper plate and screw position. Therefore, the insertion of pectoralis major tendon (PMT) may be used as an alternative landmark for appropriate plate and calcar screw position. The purpose of study is going to identify the vertical distance from PMT to a definite point on the position of locking plate.

methods30 cadaveric shoulders at the department of clinical anatomy were performed. Shoulders with osteoarthritic change (n = 5) were excluded. Finally, 25 soft cadaveric shoulders were recruited in this study. The PHILOS™ plate was placed 2 mm posterior to the bicipital groove. A humeral head (HH) was cut in the coronal plane at the level of the anterior border of the PHILOS plate with a saw. A calcar screw was inserted close to the inferior cortex of HH. Distance from the upper border of elongated combi-hole (UB-ECH) to the upper border of pectoralis major tendon (UB-PMT) was measured. The plate was then moved superiorly until the calcar screw was 12 mm superior to the inferior border of HH and the distance was repeatedly measured.

resultsThe range of distance from UB-PMT to the UB-ECH was from - 4.50 ± 7.95 mm to 6.62 ± 7.53 mm, when calcar screw was close to inferior border of HH and when the calcar screw was 12 mm superior to the inferior border of HH, respectively. The highest probability of calcar screw in proper location was 72% when UB-ECH was 3 mm above UB-PMT. DISCUSSION AND

conclusionThe GT fragment is sometimes difficult to use as an anatomic landmark for proper plate and screw position. PMT can be used as an alternative anatomic reference. UB-PMT can serve as a guide for proper calcar screw insertion. UB-ECH should be 3 mm above UB-PMT and three-fourths of cases achieved proper calcar screw location.

Indexed as

Bone ScrewsAgedAged, 80 and overBone PlatesCadaverFemaleFracture Fixation, InternalHumansHumeral HeadMaleMiddle AgedPectoralis MusclesShoulder FracturesShoulder JointTendonsA Cadaveric StudyCalcar ScrewDistanceElongated Combi-HolePectoralis Major Tendon

Identifiers

PMID34983577
PMCPMC8725298

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.