ArticleJournal of orthopaedic surgery and research2022
The proximal humeral locking plate positioning to the pectoralis major tendon in achieving the proper calcar screw location: a cadaveric study.
Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Analysis of factors associated with persistent night pain after locking plate fixation of proximal humerus fractures and development of a prediction model.BMC musculoskeletal disorders · 2026Observational
- [Research progress on medial support augmentation techniques for proximal humeral fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026Review
- Anatomical morphometry of the proximal humerus in the Vietnamese population: A comparative study using multiplanar computed tomography and cadaveric dissection.Journal of hand and microsurgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundProximal humeral fracture is the third most common of osteoporotic fracture. Most surgical cases were treated by fixation with anatomical locking plate system. The calcar screw plays a role in medial support and improving varus stability. Proximal humerus fracture in elderly patients are commonly seen with greater tuberosity (GT) fracture. The GT fragment is sometimes difficult to use as an anatomic landmark for proper plate and screw position. Therefore, the insertion of pectoralis major tendon (PMT) may be used as an alternative landmark for appropriate plate and calcar screw position. The purpose of study is going to identify the vertical distance from PMT to a definite point on the position of locking plate.
methods30 cadaveric shoulders at the department of clinical anatomy were performed. Shoulders with osteoarthritic change (n = 5) were excluded. Finally, 25 soft cadaveric shoulders were recruited in this study. The PHILOS™ plate was placed 2 mm posterior to the bicipital groove. A humeral head (HH) was cut in the coronal plane at the level of the anterior border of the PHILOS plate with a saw. A calcar screw was inserted close to the inferior cortex of HH. Distance from the upper border of elongated combi-hole (UB-ECH) to the upper border of pectoralis major tendon (UB-PMT) was measured. The plate was then moved superiorly until the calcar screw was 12 mm superior to the inferior border of HH and the distance was repeatedly measured.
resultsThe range of distance from UB-PMT to the UB-ECH was from - 4.50 ± 7.95 mm to 6.62 ± 7.53 mm, when calcar screw was close to inferior border of HH and when the calcar screw was 12 mm superior to the inferior border of HH, respectively. The highest probability of calcar screw in proper location was 72% when UB-ECH was 3 mm above UB-PMT. DISCUSSION AND
conclusionThe GT fragment is sometimes difficult to use as an anatomic landmark for proper plate and screw position. PMT can be used as an alternative anatomic reference. UB-PMT can serve as a guide for proper calcar screw insertion. UB-ECH should be 3 mm above UB-PMT and three-fourths of cases achieved proper calcar screw location.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.