Evidence map›Paper›PMID 34981128›Full record

ArticleHerz2023

Effects of TCFA on stent neointimal coverage at 9 months after EXCEL drug-eluting stent implantation assessed by OCT.

Jiao Zhang, Yuanyuan Duan, Hong Yu, Limin Jing, Yi Li, Xiaowei Jia, Dekui Jin, Huiliang Liu

Abstract read
PubMed Publisher
In one paragraph

Article in Herz, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Jiao ZhangDepartment of Cardiology, Beijing Electric Power Hospital, State Grid Corporation, Beijing, China.
Yuanyuan DuanDepartment of Geriatrics, The Second Medical Center & National Clinical Research Center for Geriatric Diseases, Chinese PLA General Hospital, Beijing, China.
Hong YuDepartment of Cardiology, Beijing Electric Power Hospital, State Grid Corporation, Beijing, China.
Limin JingDepartment of Cardiology, Beijing Electric Power Hospital, State Grid Corporation, Beijing, China.
Yi LiDepartment of Cardiology, The Third Medical Center of Chinese PLA General Hospital, No.69 Yongding Road, Haidian District, 100089, Beijing, China.
Xiaowei JiaDepartment of Cardiology, The Third Medical Center of Chinese PLA General Hospital, No.69 Yongding Road, Haidian District, 100089, Beijing, China.
Dekui JinDepartment of Cardiology, The Third Medical Center of Chinese PLA General Hospital, No.69 Yongding Road, Haidian District, 100089, Beijing, China.
Huiliang LiuDepartment of Cardiology, Beijing Electric Power Hospital, State Grid Corporation, Beijing, China. 876722113@qq.com.
Chinese PLA General Hospital · CNState Grid Corporation of China (China) · CN

Funding

beijing municipal science and technology project Z161100000516091
6 · The paper itself

Abstract

backgroundThe aim of this study was to investigate the effects of thin-cap fibroatheromas (TCFAs) on stent neointimal coverage at the 9‑month follow-up after EXCEL stent implantation assessed by optical coherence tomography (OCT).

methodsA total of 93 patients with non-ST elevation acute coronary syndrome (NSTEACS) who underwent EXCEL stent implantation were prospectively enrolled in the study and divided into a TCFA group (n = 47) and a non-TCFA group (n = 46) according to whether EXCEL stents covered the TCFAs. A TCFA was defined as a plaque with lipid content in more than one quadrant and fibrous cap thickness measuring less than 65 μm. The effect of TCFAs on stent neointimal coverage at the 9‑month follow-up after stent implantation was evaluated by OCT. The primary study endpoints were the incidence of neointimal uncoverage and stent malapposition.

resultsAt the 9‑month follow-up, the minimal lumen diameter of the TCFA group tended to be smaller (2.8 ± 0.8 vs. 2.1 ± 0.8, p = 0.08) and the diameter of stenosis in the TCFA group tended to be larger (15.1 ± 10.3% vs. 26.3 ± 15.1%, p = 0.08) than those in the non-TCFA group. The mean intimal thickness of the TCFA group was significantly lower than that of the non-TCFA group (67.2 ± 35.5 vs. 145.1 ± 48.7, p < 0.001). The uncovered struts (10.1 ± 9.7 vs. 4.8 ± 4.3, p = 0.05) and malapposed struts (2.1 ± 4.7 vs. 0.3 ± 0.5, p = 0.003) in the TCFA group were more significant than those in the non-TCFA group. Multivariate analysis showed that TCFAs and lesion types were independent predictors of incomplete neointimal coverage (p < 0.05), and lesion types were independent predictors of stent malapposition (p < 0.05).

conclusionIn patients with NSTEACS, TCFAs delayed endothelium coverage at 9 months after stent implantation, and TCFAs were independent predictors of incomplete neointimal coverage of the stent.

Indexed as

Acute Coronary SyndromeAtherosclerosisCoronary Artery DiseaseDrug-Eluting StentsPercutaneous Coronary InterventionCoronary VesselsHumansNeointimaStentsTomography, Optical CoherenceTreatment OutcomeMalappositionNeointimal coverageNon-ST-elevation acute coronary syndromeOptical coherence tomographyThin-cap fibroatheroma

Identifiers

PMID34981128
OpenAlexW4205412031

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.