ArticleBMC musculoskeletal disorders2022
Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement.
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 7 citations in OpenAlex.
- Impact of occlusal stabilization splints on global body posture: a prospective clinical trial.Clinical oral investigations · 2024Trial
- A novel multi-modal signals dynamic assessment method of idiopathic scoliosis patients for rehabilitation.Medical & biological engineering & computing · 2026Article
- Effects on Posture of a Two-Diopter Horizontal Prism Base Out on the Non-Dominant Eye.Journal of clinical medicine · 2024Article
- Multi-Modal Data Correspondence for the 4D Analysis of the Spine with Adolescent Idiopathic Scoliosis.Bioengineering (Basel, Switzerland) · 2023Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWhole body standing alignment (WBSA) in terms of biomechanics can be evaluated accurately only by referring the gravity line (GL) which lies on the gravity center (GC). Here, we introduce a method for estimating GL and simultaneous WBSA measurement using the EOS® imaging system and report on the reproducibility and reliability of the method.
methodsA 3-dimensional (3D) avatar to estimate GC was created following three steps: 3D reconstruction of the bone based on EOS images; deformation into a generic morphotype (MakeHuman statistical model) before density integration with 3D rasterization of the full body into 1-mm
resultsStatistical analyses of the data revealed that the repeatability and reproducibility of the estimation was high with intra-rater and inter-rater intraclass correlation coefficient. ≥0.999. The coordinate values of the GC and body weight estimation did not differ significantly between the avatar and force plate measurements, demonstrating the high accuracy of the method.
conclusionThis new method of estimating GC and WBSA is reliable and accurate. Application of this method could allow clinicians to quickly and qualitatively evaluate WBSA with GL with various spinal malalignment pathologies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials