Evidence map›Paper›PMID 34977536›Full record

ArticleArchives of rehabilitation research and clinical translation2021

Accuracy and Reliability of Single-Camera Measurements of Ankle Clonus and Quadriceps Hyperreflexia.

Keith Macon, Dustin Hoang, Lauren Elizondo, Kerri Kallus, James Sulzer, Kathleen Manella

Open access · goldAbstract read
In one paragraph

Article in Archives of rehabilitation research and clinical translation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 88% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Keith MaconDepartment of Mechanical Engineering, University of Texas at Austin, Austin, TX.
Dustin HoangDepartment of Mechanical Engineering, University of Texas at Austin, Austin, TX.
Lauren ElizondoSpero Rehab, Austin, TX.
Kerri KallusUniversity of St. Augustine for Health Sciences, Austin, TX.
James SulzerDepartment of Mechanical Engineering, University of Texas at Austin, Austin, TX.
Kathleen ManellaUniversity of St. Augustine for Health Sciences, Austin, TX.
The University of Texas at Austin · USUniversity of St. Augustine for Health Sciences · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate the accuracy and reliability of a simple, single-camera smartphone-based method, named the Reflex Tracker (RT) system, for measuring reflex threshold angles related to ankle clonus and quadriceps hyperreflexia.

designA prospective comparison study using a high-fidelity reference standard was constructed employing a 2 × 2 × 2 factorial design, with factors of rater (tester) type (student and experienced physical therapist), joint (ankle and knee), and repetition (2 per condition).

settingThis multicenter study was conducted at 4 outpatient rehabilitation clinics.

participantsA convenience sample of 14 individuals with a neurologic condition presented with 20 lower limbs that exhibited ankle clonus and/or quadriceps hyperreflexia and were included in the study. Also participating in the study were 8 student and 8 experienced physical therapist raters (testers) (N=16).

interventionsNot applicable.

main outcome measuresThe plantar flexor reflex threshold angle (PFRTA) related to ankle clonus and the quadriceps reflex threshold angle (QRTA) related to quadriceps hyperreflexia were quantified.

resultsPFRTA and QRTA results were compared between the smartphone RT method and synchronous 3-dimensional inertial measurement unit (IMU) sensor motion capture. Mean difference (bias) was minimal between RT and IMU measurements for PFRTA (bias≤0.2°) and QRTA (bias≤1.2°). Intrarater reliability for PFRTA ranged from 0.85-0.90 using RT and from 0.85-0.87 using IMU; QRTA ranged from 0.97-0.98 using RT and from 0.96-0.99 using IMU. Intersensor reliability for PFRTA and QRTA was 0.97 and 0.99, respectively. Minimum detectable change for PFRTA ranged from 7.1°- 8.7° and for QRTA ranged from 6.1°-8.3°.

conclusionsRT performed comparable to IMU for accurate and reliable measurement of PFRTA and QRTA to quantify ankle clonus and quadriceps hyperreflexia in clinical settings.

Indexed as

CI, confidence intervalICC, intraclass correlation coefficientIMU, inertial measurement unitLoA, limit of agreementLSD, least significant differenceMDC, minimum detectable changePFRTA, plantar flexor reflex threshold anglePlantar flexorQRTA, quadriceps reflex threshold angleReflex threshold angleRehabilitationRMS, root mean squareRTA, reflex threshold angleRT, Reflex TrackerSmartphoneSpasticity

Identifiers

PMID34977536
PMCPMC8683842
OpenAlexW3193624964

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.