ArticleTranslational pediatrics2021

A comparative study between traditional head measurement and structured light three-dimensional scanning when measuring infant head shape.

Zhi-Feng Wu, Qiong-Li Fan, Li Ming, Wang Yang, Kui-Lin Lv, Qin Chang, Wen-Zao Li, Cheng-Ju Wang, Qiu-Ming Pan, Li He and 2 more

Open access · diamondAbstract read
In one paragraph

Article in Translational pediatrics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 4 institutions in 1 country.

Zhi-Feng Wu *Department of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Qiong-Li Fan *Department of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Li MingDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Wang YangDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Kui-Lin LvDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Qin ChangDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Wen-Zao LiDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Cheng-Ju WangDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Qiu-Ming PanDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Li HeDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Bin HuDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Yu-Ping ZhangDepartment of Pediatrics, Second Affiliated Hospital of Army Medical University, Chongqing, China.
Dalian Medical University · CNArmy Medical University · CNChongqing Medical University · CNSecond Affiliated Hospital of Chongqing Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to evaluate the correlation and consistency between traditional head measurement and structured light three-dimensional (3D) scanning parameters when measuring infant skull shape.

methodsA total of 76 infants aged 3 months to 2.5 years old were included in the study. Head circumference (HC) was measured with a tape measure. The transverse, anteroposterior, and oblique diameters were measured using a spreading caliper, and the cranial vault asymmetry index (CVAI) and a cranial index (CI) of symmetry were calculated; 76 cases were measured successfully. The above indexes were measured using a structured light 3D scanning system (71 cases were measured with success). Thus, in the end, the valid data of 71 cases were analyzed, and the measurements of the two approaches were compared.

resultsThe 95% confidence interval of traditional head measurement and structured light 3D scanning was between 0.633 and 0.988. Pearson's correlation coefficient indicated a high correlation between the two methods (r=0.793-0.980). The correlation coefficients of the transverse diameter, anteroposterior diameter, and HC, and the CI of symmetry were higher than 0.9. The lowest correlation coefficient for the CVAI was 0.793. The P values of the above measurement data were all <0.001, which indicated that they were closely related. A Bland-Altman plot indicated reasonable consistency between the two methods.

conclusionsBoth traditional head measurement and structured light 3D scanning are suitable for the measurement of infant head shape. However, while traditional head measurement using a spreading caliper is economical and simple, making it suitable for general screening at a basic level, structured light 3D scanning can deliver additional parameters, which is useful for infants with an abnormal head shape. The latter is also convenient for designing a customized helmet for skull correction when needed.

Indexed as

cephalometrycorrelationhead shape measurementinfantsspreading caliperStructured light 3D scanning

Identifiers

PMID34976756
PMCPMC8649591
OpenAlexW3215954128

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.