ArticleJournal of healthcare engineering2021
Reconfigurable Architectures with High-Frequency Noise Suppression for Wearable ECG Devices.
Article in Journal of healthcare engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- R-R Interval Histogram-Based Deep Learning for 3-Class Atrial Fibrillation Screening in Garment-Type Wearable Holter Electrocardiogram Monitoring: Algorithm Development and Validation Study.JMIR medical informatics · 2026Article
- Detection of atrial fibrillation using a nonlinear Lorenz Scattergram and deep learning in primary care.BMC primary care · 2024Article
- The Effect of Comprehensive Rehabilitation Nursing on the Rehabilitation of Sports-Induced Ankle Joint Injuries.Emergency medicine international · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Recent advances in electronics and microelectronics have aided the development of low-cost devices that are widely used as well-being or preventive monitoring devices by many people. Remote health monitoring, which includes wearable sensors, actuators, and modern communication and information systems, offers effective programs that allow people to live peacefully in their own homes while also being protected in some way. High-frequency noise, power-line interface, and baseline drift are prevalent during the data-acquisition system of an ECG signal, and they can limit signal understanding. They (noises) must be isolated in order to provide an appropriate diagnostic of the patient. When removing high-frequency components (noise) from an ECG signal with an FIR filter, the critical path delay increases considerably as the filter's duration increases. To reduce high-frequency noise, simple moving average filters with pipelining and look-ahead transformation techniques are extensively used in this study. With the use of pipelining and look-ahead techniques, the only objective is to increase the clock speed of the designs. The moving average filters (conventional and proposed) were created on an Altera Cyclone IV FPGA EP4CE115F29C7 chip using the Quartus II software v13.1 tool. Finally, performance metrics such logic elements, clock speed, and power consumption were compared and studied thoroughly. The recursive pipelined 8-tap MA filter with look-ahead approach outperforms the other designs (685.48 MHz) in this investigation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.