Evidence map›Paper›PMID 34971464›Full record

ArticleMagnetic resonance in medicine2022

Twenty-four-channel high-impedance glove array for hand and wrist MRI at 3T.

Bei Zhang, Bili Wang, Justin Ho, Shota Hodono, Christopher Burke, Riccardo Lattanzi, Markus Vester, Robert Rehner, Daniel Sodickson, Ryan Brown and 1 more

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Dual-Tuned Coaxial-Transmission-Line RF Coils for HyperpolarizedIEEE transactions on bio-medical engineering · 2024
    Article
  9. Article
  10. Article
  11. Design of dual-band Coaxial-transmission-line coils with independent tuning capabilities.Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition · 2023
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Bei ZhangCenter for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.ORCID 0000-0002-9718-1594
Bili WangCenter for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
Justin HoCenter for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
Shota HodonoCentre for Advanced Imaging, Queensland University, Brisbane, Queensland, Australia.
Christopher BurkeNYU Langone Orthopedic Hospital, New York, New York, USA.
Riccardo LattanziCenter for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
Markus VesterSiemens Healthcare GmbH, Erlangen, Germany.
Robert RehnerSiemens Healthcare GmbH, Erlangen, Germany.
Daniel SodicksonCenter for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
Ryan BrownCenter for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
Martijn CloosCenter for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.

Funding

TR&D 4: Revealing Microstructure: Biophysical modeling and validation for discovery and clinical careP41EB017183 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Christopher M Collins · 2014 to 2026
$19.3M
Novel Software Tools for Rational Design and Assessment of MR CoilsR01EB024536 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Riccardo Lattanzi · 2017 to 2026
$5.1M
NIBIB NIH HHS P41 EB017183NIBIB NIH HHS R01 EB024536
6 · The paper itself

Abstract

purposeTo present a novel 3T 24-channel glove array that enables hand and wrist imaging in varying postures.

methodsThe glove array consists of an inner glove holding the electronics and an outer glove protecting the components. The inner glove consists of four main structures: palm, fingers, wrist, and a flap that rolls over on top. Each structure was constructed out of three layers: a layer of electrostatic discharge flame-resistant fabric, a layer of scuba neoprene, and a layer of mesh fabric. Lightweight and flexible high impedance coil (HIC) elements were inserted into dedicated tubes sewn into the fabric. Coil elements were deliberately shortened to minimize the matching interface. Siemens Tim 4G technology was used to connect all 24 HIC elements to the scanner with only one plug.

resultsThe 24-channel glove array allows large motion of both wrist and hand while maintaining the SNR needed for high-resolution imaging.

conclusionIn this work, a purpose-built 3T glove array that embeds 24 HIC elements is demonstrated for both hand and wrist imaging. The 24-channel glove array allows a great range of motion of both the wrist and hand while maintaining a high SNR and providing good theoretical acceleration performance, thus enabling hand and wrist imaging at different postures to extract kinematic information.

Indexed as

Magnetic Resonance ImagingWristElectric ImpedanceEquipment DesignHandPhantoms, Imagingdynamic imaginghand imaginghigh impedance coilMRI RF arraywrist imaging

Identifiers

PMID34971464
PMCPMC8847333

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.