ArticleMagnetic resonance in medicine2022
Twenty-four-channel high-impedance glove array for hand and wrist MRI at 3T.
Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Deuterium 1-Channel Transmit/16-Channel High Impedance Receive Array Combined With 16-ChannelMagnetic resonance in medicine · 2026Article
- Suppressing loop current of shielded loops at fundamental resonance.Scientific reports · 2026Article
- A 60-channel high-density flexible receive array for pediatric abdominal MRI.Magnetic resonance in medicine · 2025Article
- A modular system of flexible receive-only coil arrays for 3 T Magnetic Resonance Imaging.Zeitschrift fur medizinische Physik · 2025Article
- Open-transmit and flexible receiver array for high resolution ultrahigh-field fMRI of the human sensorimotor cortex.Communications biology · 2025Article
- The RF Cap: A 26-channel flexible RF coil cap for optimized concurrent TMS/fMRI experiments at 3T.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- Wireless, customizable coaxially shielded coils for magnetic resonance imaging.Science advances · 2024Article
- Dual-Tuned Coaxial-Transmission-Line RF Coils for HyperpolarizedIEEE transactions on bio-medical engineering · 2024Article
- Article
- Double cross magnetic wall decoupling for quadrature transceiver RF array coils using common-mode differential-mode resonators.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2023Article
- Design of dual-band Coaxial-transmission-line coils with independent tuning capabilities.Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition · 2023Article
- A flexible MRI coil based on a cable conductor and applied to knee imaging.Scientific reports · 2022Article
- Twenty-four-channel high-impedance glove array for hand and wrist MRI at 3T.Magnetic resonance in medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
purposeTo present a novel 3T 24-channel glove array that enables hand and wrist imaging in varying postures.
methodsThe glove array consists of an inner glove holding the electronics and an outer glove protecting the components. The inner glove consists of four main structures: palm, fingers, wrist, and a flap that rolls over on top. Each structure was constructed out of three layers: a layer of electrostatic discharge flame-resistant fabric, a layer of scuba neoprene, and a layer of mesh fabric. Lightweight and flexible high impedance coil (HIC) elements were inserted into dedicated tubes sewn into the fabric. Coil elements were deliberately shortened to minimize the matching interface. Siemens Tim 4G technology was used to connect all 24 HIC elements to the scanner with only one plug.
resultsThe 24-channel glove array allows large motion of both wrist and hand while maintaining the SNR needed for high-resolution imaging.
conclusionIn this work, a purpose-built 3T glove array that embeds 24 HIC elements is demonstrated for both hand and wrist imaging. The 24-channel glove array allows a great range of motion of both the wrist and hand while maintaining a high SNR and providing good theoretical acceleration performance, thus enabling hand and wrist imaging at different postures to extract kinematic information.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.