ReviewCurrent reviews in musculoskeletal medicine2021
Total Knee Arthroplasty and Intra-Articular Pressure Sensors: Can They Assist Surgeons with Intra-Operative Decisions?
Review in Current reviews in musculoskeletal medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- A comparison on the clinical outcomes of using intraoperative load sensors versus manual balancing in total knee arthroplasty: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2025Pooled it
- Mean distraction force applied in tension-controlled ligament-balanced total knee arthroplasty: A systematic review and meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Pooled it
- Medial-pivot total knee arthroplasty demonstrates more constrained mid-flexion gait kinematics than posterior-stabilised total knee arthroplasty under standardised soft-tissue balancing: A randomised controlled trial with a healthy reference cohort.Journal of experimental orthopaedics · 2026Article
- Alignment Philosophies in Total Knee Arthroplasty: A Comprehensive Narrative Review.Arthroplasty today · 2026Article
- Robotic-Assisted Isolated Polyethylene Exchange: A Novel Surgical Technique.Arthroplasty today · 2025Article
- Caliper verification and gap measurements of kinematic alignment total knee arthroplasty utilizing an imageless, accelerometer-based navigation system.Knee surgery & related research · 2025Article
- Reliability of pre-resection ligament tension assessment in imageless robotic assisted total knee replacement.Arthroplasty (London, England) · 2024Article
- SMART (self- monitoring analysis and reporting technology) and sensor based technology applications in trauma and orthopaedic surgery.Journal of orthopaedics · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purpose of reviewSoft tissue imbalance, presenting as instability or stiffness, is an important cause of revision total knee arthroplasty (TKA). Traditional methods of determining soft tissue balance of the knee lack precision and are not reliable between operators. Use of intra-operative pressure sensors offers the potential to identify and avoid soft tissue imbalance following TKA. This review aims to summarise the literature supporting the clinical indication for the use of intra-articular pressure sensors during TKA. RECENT
findingsAnalytical validation studies suggest that intra-operative pressure sensors demonstrate 'moderate' to 'good' intra-observer reliability and 'good' to 'excellent' interobserver reliability throughout the flexion arc. However, there are important errors associated with measurements when devices are used out-with the stated guidelines and clinicians should be aware of the limitations of these devices in isolation. Current evidence regarding patient benefit is conflicting. Despite positive early results, several prospective studies have subsequently failed to demonstrate significant differences in overall survival, satisfaction, and patient-reported outcome measures within 1 year of surgery. Surgeon-defined soft tissue stability appears to be significantly different from the absolute pressures measured by the intra-operative sensor. Whilst it could be argued that this confirms the need for intra-articular sensor guidance in TKA; the optimal 'target' balance remains unclear and the relationship with outcome in patients is not determined. Future research should (1) identify a suitable reference standard for comparison; (2) improve the accuracy of the sensor outputs; and (3) demonstrate that sensor-assisted TKA leads to patient benefit in patient-reported outcome measures and/or enhanced implant survival.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.