Evidence map›Paper›PMID 34960344›Full record

ArticleSensors (Basel, Switzerland)2021

Bendductor-Transformer Steel Magnetomechanical Force Sensor.

Przemysław Grenda, Monika Kutyła, Michał Nowicki, Tomasz Charubin

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Przemysław GrendaWarsaw University of Technology, Institute of Metrology and Biomedical Engineering, A. Boboli 8, 02-525 Warsaw, Poland.
Monika KutyłaWarsaw University of Technology, Institute of Metrology and Biomedical Engineering, A. Boboli 8, 02-525 Warsaw, Poland.ORCID 0000-0002-7760-8589
Michał NowickiWarsaw University of Technology, Institute of Metrology and Biomedical Engineering, A. Boboli 8, 02-525 Warsaw, Poland.ORCID 0000-0003-2513-952X
Tomasz CharubinWarsaw University of Technology, Institute of Metrology and Biomedical Engineering, A. Boboli 8, 02-525 Warsaw, Poland.ORCID 0000-0001-5076-5288

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, the design and investigation of an innovative force sensor, based on the Villari effect, is presented. The sensor was built from electrical steel, in a pressductor pattern, but working in bending load mode. The results of the experimental research allowed for the evaluation of transducer's performance, mitigation of measurement hysteresis, and optimization of its functional parameters. Several issues have been examined, among them the selection of supply and measured signals, the measured values' impact on measurement hysteresis, harmonic analysis, and the selection of proper current waveforms and frequencies. The proposed sensor is robust, made from inexpensive materials, and has high sensitivity, as compared to other magnetoelastic sensors. It has much higher stress sensitivity than other magnetoelastic sensors due to deformation mode. Based on the tests, its measuring range can be defined as 0.5-5 N with a near-linear characteristic, SNR of 46 dB, and 0.11 N uncertainty.

Indexed as

SteelTransducersEquipment DesignSteelforce sensormagnetoelastic effectVillari effect

Identifiers

PMID34960344
PMCPMC8707221

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.