ArticleMagnetic resonance in medicine2022
Safety of MRI in patients with retained cardiac leads.
Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Weight-Guided Constraints for Body Model and Lead Selection in Pediatric CIED MRI Safety Simulations.ArXiv · 2026Article
- Predictors of late gadolinium enhancement cardiac MRI image quality in patients with cardiac implantable electronic devices.Heart rhythm O2 · 2025Article
- Comparative study of radiofrequency heating in deep brain stimulation devices during MRI at 1.5 T and 0.55 T: Challenging the assumption of safety at low field strengths.Magnetic resonance in medicine · 2025Article
- MRI in Patients with Cardiovascular Implantable Electronic Devices and Fractured or Abandoned Leads.Radiology. Cardiothoracic imaging · 2024Article
- Age Matters: A Comparative Study of RF Heating of Epicardial and Endocardial Electronic Devices in Pediatric and Adult Phantoms during Cardiothoracic MRI.Diagnostics (Basel, Switzerland) · 2023Article
- Implants talk to each-other: RF heating changes when two DBS leads are present simultaneously during MRI.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023Article
- RF-induced heating of capped and uncapped abandoned epicardial leads during MRI at 1.5 T and 3 T.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023Article
- Rapid prediction of MRI-induced RF heating of active implantable medical devices using machine learning.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023Article
- Application of Machine learning to predict RF heating of cardiac leads during magnetic resonance imaging at 1.5 T and 3 T: A simulation study.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2023Article
- Article
- The Position and Orientation of the Pulse Generator Affects MRI RF Heating of Epicardial Leads in Children.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2022Article
- Safety of MRI in patients with retained cardiac leads.Magnetic resonance in medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeTo evaluate the safety of MRI in patients with fragmented retained leads (FRLs) through numerical simulation and phantom experiments.
methodsElectromagnetic and thermal simulations were performed to determine the worst-case RF heating of 10 patient-derived FRL models during MRI at 1.5 T and 3 T and at imaging landmarks corresponding to head, chest, and abdomen. RF heating measurements were performed in phantoms implanted with reconstructed FRL models that produced highest heating in numerical simulations. The potential for unintended tissue stimulation was assessed through a conservative estimation of the electric field induced in the tissue due to gradient-induced voltages developed along the length of FRLs.
resultsIn simulations under conservative approach, RF exposure at B
conclusionsSimulation and experimental results indicate that patients with FRLs can be scanned safely at both 1.5 T and 3 T with most clinical pulse sequences.