ArticleFrontiers in bioengineering and biotechnology2021

Factors Associated with Energy Efficiency of Focused Ultrasound Through the Skull: A Study of 3D-Printed Skull Phantoms and Its Comparison with Clinical Experiences.

Chanho Kong, So Hee Park, Jaewoo Shin, Hee Gyu Baek, Juyoung Park, Young Cheol Na, Won Seok Chang, Jin Woo Chang

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Role of PScientific reports · 2025
    Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Chanho KongDepartment of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
So Hee ParkDepartment of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
Jaewoo ShinDepartment of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
Hee Gyu BaekMedical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, South Korea.
Juyoung ParkMedical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, South Korea.
Young Cheol NaDepartment of Neurosurgery, Catholic Kwandong University College of Medicine, International St Mary's Hospital, Incheon, South Korea.
Won Seok ChangDepartment of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
Jin Woo ChangDepartment of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

While focused ultrasound (FUS) is non-invasive, the ultrasound energy is attenuated by the skull which results in differences in energy efficiency among patients. In this study, we investigated the effect of skull variables on the energy efficiency of FUS. The thickness and density of the skull and proportion of the trabecular bone were selected as factors that could affect ultrasound energy transmittance. Sixteen 3D-printed skull models were designed and fabricated to reflect the three factors. The energy of each phantom was measured using an ultrasonic sound field energy measurement system. The thickness and proportion of trabecular bone affected the attenuation of transmitted energy. There was no difference in the density of the trabecular bone. In clinical data, the trabecular bone ratio showed a significantly greater correlation with dose/delivered energy than that of thickness and the skull density ratio. Currently, for clinical non-thermal FUS, the data are not sufficient, but we believe that the results of this study will be helpful in selecting patients and appropriate parameters for FUS treatment.

Indexed as

3D printblood-brain barrierenergy transmissionfocused ultrasoundskull density ratioskull factor

Identifiers

PMID34957077
PMCPMC8708563

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.