Evidence map›Paper›PMID 34956361›Full record

ArticleGastroenterology research and practice2021

Endoscopic Delivery Method Using a Retrieval Net for Patients with Small-Bowel Capsule Endoscopy Stagnation in the Stomach.

Akihiko Sumioka, Shiro Oka, Akiyoshi Tsuboi, Issei Hirata, Sumio Iio, Hidenori Tanaka, Ken Yamashita, Takahiro Kotachi, Ryo Yuge, Yuji Urabe and 1 more

Open access · goldAbstract read
In one paragraph

Article in Gastroenterology research and practice, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Akihiko SumiokaDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Shiro OkaDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.ORCID https://orcid.org/0000-0002-1652-0743
Akiyoshi TsuboiDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Issei HirataDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Sumio IioDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Hidenori TanakaDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Ken YamashitaDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Takahiro KotachiDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Ryo YugeDepartment of Gastroenterology and Metabolism, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Yuji UrabeDivision of Regeneration and Medicine Center for Translational and Clinical Research, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Shinji TanakaDepartment of Endoscopy, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
Hiroshima University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With the increasing use of capsule endoscopy (CE), screening tests for the small bowel can be performed with minimal invasiveness. However, occasionally, the entire small bowel cannot be observed because of decreased peristalsis of the stomach. For such cases, we perform delivery of CE by an endoscope. We retrospectively examined the usefulness of the endoscopic delivery method using a retrieval net for patients with CE stagnation in the stomach. From 2,270 patients who underwent small-bowel CE at Hiroshima University Hospital from January 2013 to January 2020, 29 consecutive patients (1.3% of the total number) in whom the small bowel could not be observed due to CE stagnation in the stomach at the time of the initial CE underwent the endoscopic delivery method using a retrieval net for secondary small-bowel CE. This study included 16 male (55%) and 13 female (45%) patients with a mean age of 69.2 ± 13.2 years. 11 patients (38%) had a history of gastrointestinal surgical resection. The entire small bowel could be observed in 19 patients (66%), and CE reached the terminal ileum in the remaining patients. A history of gastrointestinal surgical resection was significantly more frequent in the group where the entire small bowel could not be observed. The rate of small-bowel lesion detection was 55% (16/29). There were no adverse events associated with our endoscopic delivery method. Thus, the endoscopic delivery method using a retrieval net for patients with initial CE stagnation in the stomach may be safe and useful for the detection of small-bowel lesions.

Identifiers

PMID34956361
PMCPMC8702352
OpenAlexW4200531834

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.