Evidence map›Paper›PMID 34951655›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2022

A minimally invasive cerclage of the tibia in a modified Goetze technique: operative technique and first clinical results.

Stefan Förch, Jan Reuter, Franziska von der Helm, Leonard Lisitano, Christopher Hartwig, Sabrina Sandriesser, Stefan Nuber, Edgar Mayr

Open access · hybridAbstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Biomechanical evaluation of cerclage wiring in plated tibia fractures using human and synthetic specimens.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Stefan Förch *Department of Trauma, Orthopaedics, Plastic and Hand Surgery, University Hospital Augsburg, Augsburg, Germany. stefan.foerch@uk-augsburg.de.
Jan Reuter *Department of Trauma, Orthopaedics, Plastic and Hand Surgery, University Hospital Augsburg, Augsburg, Germany.
Franziska von der HelmDepartment of Trauma, Orthopaedics, Plastic and Hand Surgery, University Hospital Augsburg, Augsburg, Germany.
Leonard LisitanoDepartment of Trauma, Orthopaedics, Plastic and Hand Surgery, University Hospital Augsburg, Augsburg, Germany.
Christopher HartwigDepartment of Trauma, Orthopaedics, Plastic and Hand Surgery, University Hospital Augsburg, Augsburg, Germany.
Sabrina SandriesserInstitute for Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Murnau, Germany.
Stefan NuberDepartment of Trauma, Orthopaedics, Plastic and Hand Surgery, University Hospital Augsburg, Augsburg, Germany.
Edgar MayrDepartment of Trauma, Orthopaedics, Plastic and Hand Surgery, University Hospital Augsburg, Augsburg, Germany.
University Hospital Augsburg · DEBerufsgenossenschaftliche Unfallklinik Murnau · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn spiral fractures of the tibia, the stability of an osteosynthesis may be significantly increased by additive cerclages and, according to biomechanical studies, be brought into a state that allows immediate full weight bearing. As early as 1933, Goetze described a minimally invasive technique for classic steel cerclages. This technique was modified, so that it can be used for modern cable cerclages in a soft part saving way.

methodAfter closed reduction, an 8 Fr redon drain is first inserted in a minimally invasive manner, strictly along the bone and placed around the tibia via 1 cm incisions on the anterolateral and dorsomedial tibial edges using a curette and a tissue protection sleeve. Via this drain, a 1.7 mm cable cerclage can be inserted. The fracture is then anatomically reduced while simultaneously tightening the cerclage. Subsequently, a nail or a minimally invasive plate osteosynthesis is executed using the standard technique. Using the hospital documentation system, data of patients that were treated with additional cerclages for tibial fractures between 01/01/2014 and 06/30/2020 were subjected to a retrospective analysis for postoperative complications (wound-healing problems, infections and neurovascular injury). Inclusion criteria were: operatively treated tibial fractures, at least one minimally invasive additive cerclage, and age of 18 years or older. Exclusion criteria were: periprosthetic or pathological fractures and the primary need of reconstructive plastic surgery. SPSS was used for statistical analysis.

results96 tibial shaft spiral fractures were treated with a total of 113 additive cerclages. The foregoing resulted in 10 (10.4%) postoperative wound infections, 7 of which did not involve the cerclage. One lesion of the profundal peroneal nerve was detected, which largely declined after cerclage removal. In 3 cases, local irritation from the cerclage occurred and required removal of material.

conclusionIn the described technique, cerclages may be inserted additively at the tibia in a minimally invasive manner and with a few complications, thus significantly increasing the stability of an osteosynthesis. How this ultimately affects fracture healing is the subject of an ongoing study.

Indexed as

Tibial FracturesAdolescentBone PlatesFracture Fixation, InternalFracture HealingHumansMinimally Invasive Surgical ProceduresRetrospective StudiesTibiaClinical resultsComplicationsGoetze cerclageMinimalle invasive cerclageOperative techniqueTibial fracture

Identifiers

PMID34951655
PMCPMC9360161
OpenAlexW4200607641

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.