Evidence map›Paper›PMID 34947897›Full record

ArticleLife (Basel, Switzerland)2021

Similar Biomechanical Behavior in Gait Analysis between Ceramic-on-Ceramic and Ceramic-on-XLPE Total Hip Arthroplasties.

Athanasios Triantafyllou, Georgios Papagiannis, Vasileios S Nikolaou, Panayiotis J Papagelopoulos, George C Babis

Abstract read
In one paragraph

Article in Life (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Athanasios TriantafyllouOrthopaedic Research and Education Center "P.N.Soucacos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", 1st Department of Orthopaedic Surgery, "Attikon" University General Hospital, Medical School, National and Kapodistrian University of Athens, 12462 Athens, Greece.
Georgios PapagiannisOrthopaedic Research and Education Center "P.N.Soucacos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", 1st Department of Orthopaedic Surgery, "Attikon" University General Hospital, Medical School, National and Kapodistrian University of Athens, 12462 Athens, Greece.
Vasileios S Nikolaou2nd Department of Orthopaedic Surgery, Konstantopouleio General Hospital, Nea Ionia, Medical School, National and Kapodistrian University of Athens, 14233 Athens, Greece.
Panayiotis J PapagelopoulosOrthopaedic Research and Education Center "P.N.Soucacos", Biomechanics and Gait Analysis Laboratory "Sylvia Ioannou", 1st Department of Orthopaedic Surgery, "Attikon" University General Hospital, Medical School, National and Kapodistrian University of Athens, 12462 Athens, Greece.
George C Babis2nd Department of Orthopaedic Surgery, Konstantopouleio General Hospital, Nea Ionia, Medical School, National and Kapodistrian University of Athens, 14233 Athens, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In vitro measurements are widely used to implement gait kinematic and kinetic parameters to predict THA wear rate. Clinical tests of materials and designs are crucial to prove the accuracy and validate such measurements. This research aimed to examine the effect of CoC and CoXLPE kinematics and kinetics on wear during gait, the essential functional activity of humans, by comparing in vivo data to in vitro results. Our study hypothesis was that both implants would present the same hip joint kinematics and kinetics during gait. In total, 127 unilateral primary cementless total hip arthroplasties were included in the research. There were no statistically significant differences observed at mean peak abduction, flexion, and extension moments and THA kinematics between the two groups. THA gait kinematics and kinetics are crucial biomechanical inputs associated with implant wear. In vitro studies report less wear in CoC than CoXLPE when tested in a matched gait kinematic protocol. Our findings confirm that both implants behave identically in terms of kinematics in a clinical environment, thus strengthening CoC advantage in in vitro results. Correlated to all other significant factors that affect THA wear, it could address in a complete prism the wear on CoC and CoXLPE.

Indexed as

ceramic on ceramic THA loadingceramic on XLPE wearTHA kinematicsTHA kineticstotal hip arthroplasty biomechanics

Identifiers

PMID34947897
PMCPMC8704359

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.