ArticleMicromachines2021
Mixing Performance of a Passive Micro-Mixer with Mixing Units Stacked in Cross Flow Direction.
Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Design and Analysis of a Passive Micromixer Based on Multiple Passages.Micromachines · 2025Article
- Design and Mixing Analysis of a Passive Micromixer with Circulation Promoters.Micromachines · 2024Article
- Mixing Performance of a Passive Micromixer Based on Split-to-Circulate (STC) Flow Characteristics.Micromachines · 2024Article
- Design and Mixing Analysis of a Passive Micromixer Based on Curly Baffles.Micromachines · 2023Article
- A Modified-Herringbone Micromixer for Assessing Zebrafish Sperm (MAGS).Micromachines · 2023Article
- Mixing Performance of a Passive Micromixer Based on Multiple Baffles and Submergence Scheme.Micromachines · 2023Article
- Influence of Structural Parameters on the Performance of an Asymmetric Rhombus Micromixer with Baffles.Micromachines · 2023Article
- Editorial for the Special Issue on Analysis, Design and Fabrication of Micromixers II.Micromachines · 2022Article
- Mixing Performance of the Modified Tesla Micromixer with Tip Clearance.Micromachines · 2022Article
- Mixing Enhancement of a Passive Micromixer with Submerged Structures.Micromachines · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
A new passive micro-mixer with mixing units stacked in the cross flow direction was proposed, and its performance was evaluated numerically. The present micro-mixer consisted of eight mixing units. Each mixing unit had four baffles, and they were arranged alternatively in the cross flow and transverse direction. The mixing units were stacked in four different ways: one step, two step, four step, and eight step stacking. A numerical study was carried out for the Reynolds numbers from 0.5 to 50. The corresponding volume flow rate ranged from 6.33 μL/min to 633 μL/min. The mixing performance was analyzed in terms of the degree of mixing (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.