Evidence map›Paper›PMID 34944675›Full record

ArticleBiomedicines2021

Mitochondrial Respiration of Platelets: Comparison of Isolation Methods.

Andrea Vernerova, Luiz Felipe Garcia-Souza, Ondrej Soucek, Milan Kostal, Vit Rehacek, Lenka Kujovska Krcmova, Erich Gnaiger, Ondrej Sobotka

Open access · goldAbstract read
In one paragraph

Article in Biomedicines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Andrea VernerovaDepartment of Analytical Chemistry, Faculty of Pharmacy in Hradec Kralove, Charles University, Akademika Heyrovskeho 1203/8, 500 05 Hradec Kralove, Czech Republic.
Luiz Felipe Garcia-SouzaOroboros Instruments GmbH, Schoepfstrasse 18, A-6020 Innsbruck, Austria.ORCID 0000-0003-1474-5428
Ondrej SoucekDepartment of Clinical Immunology and Allergology, University Hospital Hradec Kralove, Sokolska 581, 500 05 Hradec Kralove, Czech Republic.ORCID 0000-0003-3137-4200
Milan Kostal4th Department of Internal Medicine-Hematology, University Hospital Hradec Kralove, Sokolska 581, 500 05 Hradec Kralove, Czech Republic.
Vit RehacekTransfusion Department, University Hospital Hradec Kralove, Sokolska 581, 500 05 Hradec Kralove, Czech Republic.
Lenka Kujovska KrcmovaDepartment of Analytical Chemistry, Faculty of Pharmacy in Hradec Kralove, Charles University, Akademika Heyrovskeho 1203/8, 500 05 Hradec Kralove, Czech Republic.
Erich GnaigerOroboros Instruments GmbH, Schoepfstrasse 18, A-6020 Innsbruck, Austria.
Ondrej Sobotka3rd Department of Internal Medicine-Metabolic Care and Gerontology, University Hospital Hradec Kralove, Sokolska 581, 500 05 Hradec Kralove, Czech Republic.ORCID 0000-0002-6453-148X
University Hospital Hradec Králové · CZCharles University · CZInnsbruck Medical University · ATOroboros Instruments (Austria) · AT

Funding

European Cooperation in Science and Technology CA15203European Union's Horizon 2020 research and innovation programme under grant agreement No. 859770, NextGen-O2k projectProject SVV 260 548, the University Hospital in Hradec Kralove MH CZ - DRO UHHK, 00179906
6 · The paper itself

Abstract

Multiple non-aggregatory functions of human platelets (PLT) are widely acknowledged, yet their functional examination is limited mainly due to a lack of standardized isolation and analytic methods. Platelet apheresis (PA) is an established clinical method for PLT isolation aiming at the treatment of bleeding diathesis in severe thrombocytopenia. On the other hand, density gradient centrifugation (DC) is an isolation method applied in research for the analysis of the mitochondrial metabolic profile of oxidative phosphorylation (OXPHOS) in PLT obtained from small samples of human blood. We studied PLT obtained from 29 healthy donors by high-resolution respirometry for comparison of PA and DC isolates. ROUTINE respiration and electron transfer capacity of living PLT isolated by PA were significantly higher than in the DC group, whereas plasma membrane permeabilization resulted in a 57% decrease of succinate oxidation in PA compared to DC. These differences were eliminated after washing the PA platelets with phosphate buffer containing 10 mmol·L

Indexed as

density gradient centrifugationflow cytometryhigh-resolution respirometryhuman plateletsmitochondriaoxidative phosphorylationplatelet apheresisthrombocytes

Identifiers

PMID34944675
PMCPMC8698846
OpenAlexW4200156767

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.