Evidence map›Paper›PMID 34943289›Full record

ArticleChildren (Basel, Switzerland)2021

The Use of a Disposable Umbilical Clamp to Secure an Umbilical Venous Catheter in Neonatal Emergencies-An Experimental Feasibility Study.

Bernhard Schwaberger, Christoph Schlatzer, Daniel Freidorfer, Marlies Bruckner, Christina H Wolfsberger, Lukas P Mileder, Gerhard Pichler, Berndt Urlesberger

Open access · goldAbstract read
In one paragraph

Article in Children (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Stabilization and Resuscitation of Newborns.Children (Basel, Switzerland) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Bernhard SchwabergerDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0001-5499-3712
Christoph SchlatzerDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria.
Daniel FreidorferMedizinercorps Graz, Austrian Red Cross Federal Association Styria, 8010 Graz, Austria.
Marlies BrucknerDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0003-3429-7597
Christina H WolfsbergerDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0002-9770-3487
Lukas P MilederDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0003-3932-665X
Gerhard PichlerDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria.ORCID 0000-0003-2405-7143
Berndt UrlesbergerDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria.
Medical University of Graz · ATAustrian Red Cross · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent guidelines recommend the umbilical venous catheter (UVC) as the optimal vascular access method during neonatal resuscitation. In emergencies the UVC securement may be challenging and time-consuming. This experimental study was designed to test the feasibility of new concepts for the UVC securement. Umbilical cord remnants were catheterized with peripheral catheters and secured with disposable umbilical clamps. Three different securement techniques were investigated. Secure 1: the disposable umbilical clamp was closed at the level of the inserted catheter. Secure 2: the clamp was closed at the junction of the catheter and plastic wings. Secure 3: the setting of Secure 2 was combined with an umbilical tape. The main outcomes were the feasibility of fluid administration and the maximum force to release the securement. This study shows that inserting peripheral catheters into the umbilical vein and securing them with disposable umbilical clamps is feasible. Rates of lumen obstruction and the effectiveness of the securement were superior with Secure 2 and 3 compared to Secure 1. This new approach may be a rewarding option for umbilical venous catheterization and securement particularly in low-resource settings and for staff with limited experience in neonatal emergencies. However, although promising, these results need to be confirmed in clinical trials before being introduced into clinical practice.

Indexed as

disposable umbilical clampneonatal emergencyneonatal resuscitationnewborn(secure method for) umbilical venous catheter (UVC)UVC securement techniquevascular access

Identifiers

PMID34943289
PMCPMC8699894
OpenAlexW3217170225

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked