Evidence map›Paper›PMID 34941930›Full record

SynthesisPloS one2021

The diagnostic accuracy and prognostic value of OCT for the evaluation of the visual function in children with a brain tumour: A systematic review.

Myrthe A Nuijts, Saskia M Imhof, Nienke Veldhuis, Coco C Dekkers, Antoinette Y N Schouten-van Meeteren, Inge Stegeman

Open access · goldAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Myrthe A NuijtsDepartment of Ophthalmology, University Medical Centre Utrecht, Utrecht, The Netherlands.ORCID 0000-0002-6362-0122
Saskia M ImhofDepartment of Ophthalmology, University Medical Centre Utrecht, Utrecht, The Netherlands.
Nienke VeldhuisFaculty of Medicine, Utrecht University, Utrecht, The Netherlands.
Coco C DekkersFaculty of Medicine, Utrecht University, Utrecht, The Netherlands.
Antoinette Y N Schouten-van MeeterenDepartment of Neuro-Oncology, Princess Máxima Centre for Paediatric Oncology, Utrecht, The Netherlands.
Inge StegemanDepartment of Ophthalmology, University Medical Centre Utrecht, Utrecht, The Netherlands.ORCID 0000-0001-5154-7178
University Medical Center Utrecht · NLUtrecht University · NLPrincess Máxima Center · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo systematically review the evidence on the diagnostic accuracy and prognostic value of retinal optical coherence tomography (OCT) to detect visual acuity (VA) or visual field (VF) loss in children with a brain tumour.

methodsPubMed, Embase and Cochrane Library databases were searched from inception to February 2021. We included studies evaluating retinal OCT and standard visual function parameters (VA and or VF) in children with a brain tumour. Two authors independently extracted data from each included study. They also assessed the methodological quality of the studies using the QUADAS-2 or QUIPS tool. The diagnostic accuracy of OCT was evaluated with receiver operating characteristic analysis, sensitivity, specificity, positive predictive value and negative predictive value. The prognostic value of OCT was evaluated with predictive measures (odds ratio).

resultsWe included five diagnostic studies, with a total of 186 patients, all diagnosed with optic pathway glioma. No prognostic studies were eligible for inclusion. Included studies evaluated either retinal nerve fiber layer (RNFL) thickness or ganglion cell layer-inner plexiform layer (GCL-IPL) thickness. There was considerable heterogeneity between OCT devices, OCT protocols, visual function parameters and threshold values. Sensitivity and specificity for RNFL thickness measurement ranged from 60.0% to 100.0% and 76.6% to 100%, respectively. For GCL-IPL thickness measurement, area under the curve ranged from 0.91 to 0.98 for different diameters.

conclusionThe literature regarding the diagnostic accuracy and prognostic value of OCT parameters in children with a brain tumour is scarce. Due to heterogeneity and a considerable risk of bias of included studies, we cannot draw solid conclusions regarding the accuracy of retinal OCT. Future research should investigate the potential of OCT as diagnostic and prognostic tool for the evaluation of the visual function and detection of visual impairment in children with any type of brain tumour.

Indexed as

Tomography, Optical CoherenceVisual AcuityVisual Field TestsBrain NeoplasmsChildHumansOptic Nerve GliomaPrognosis

Identifiers

PMID34941930
PMCPMC8699950
OpenAlexW4200024254

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.