Evidence map›Paper›PMID 34941641›Full record

ArticleTomography (Ann Arbor, Mich.)2021

Low kV Computed Tomography of Parenchymal Abdominal Organs-A Systematic Animal Study of Different Contrast Media Injection Protocols.

Daniel Overhoff, Gregor Jost, Michael McDermott, Olaf Weber, Hubertus Pietsch, Stefan O Schoenberg, Ulrike Attenberger

Open access · goldAbstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Daniel OverhoffDepartment of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, 68167 Mannheim, Germany.ORCID 0000-0001-5881-4769
Gregor JostMR and CT Contrast Media Research, Bayer AG, 13353 Berlin, Germany.
Michael McDermottRadiology Research and Development, Bayer AG, 13353 Berlin, Germany.
Olaf WeberRadiology Research and Development, Bayer AG, 13353 Berlin, Germany.
Hubertus PietschMR and CT Contrast Media Research, Bayer AG, 13353 Berlin, Germany.
Stefan O SchoenbergDepartment of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, 68167 Mannheim, Germany.
Ulrike AttenbergerDepartment of Diagnostic and Interventional Radiology, University Hospital Bonn, Rheinische-Friedrich-Wilhelms-Universität Bonn, 53127 Bonn, Germany.
Bayer (Germany) · DEHeidelberg University · DEUniversity of Bonn · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate multiphase low kV computed tomography (CT) imaging of the abdomen with reduced contrast media (CM) dose using different injection protocols.

methodsTwo injection protocols were evaluated for use with low kV (80 kV) multiphase abdominal imaging in comparison to the standard procedure acquired at 120 kV (500 mgI/kg; 5 mL/s). This evaluation was conducted in a highly standardized animal study (5 Goettingen minipigs). The low kV protocols consisted of (a) a single-flow (SF) injection with 40% reduced CM dose and injection rate (300 mgI/kg; 3 mL/s) and (b) a DualFlow (DF) injection protocol consisting of 60%/40% contrast to saline ratio administered at 5 mL/s. Dynamic CT was first performed within representative liver regions to determine optimal contrast phases, followed by evaluation of the three protocols in multiphase abdominal CT imaging. The evaluation criteria included contrast enhancement (CE) of abdominal organs and vasculature.

resultsThe 80 kV DF injection protocol showed similar CE of the abdominal parenchymatous organs and vessels to the 120 kV reference and the 80 kV SF protocol. Hepatic parenchyma showed comparable CT values for all contrast phases. In particular, in the portal venous parenchymal phase, the 80 kV DF protocol demonstrated higher hepatic parenchymal enhancement; however, results were statistically non-significant. Similarly, CE of the kidney, pancreas, and abdominal arterial/venous vessels showed no significant differences between injection protocols.

conclusionsAdapted SF and DF injection protocols with reduced IDR/iodine load offer the potential to calibrate optimal CM doses to the tube voltage in abdominal multiphase low kV CT imaging. The data suggest that the DF approach allows the use of predefined injection protocols and adaption of the contrast to saline ratio to an individualized kV setting and yields the potential for patient-individualized CM adaption.

Indexed as

Contrast MediaIodineAbdomenAnimalsHumansSwineSwine, MiniatureTomography, X-Ray ComputedContrast MediaIodineabdominal imagingangiographycomputed tomographycontrast mediaiodine delivery ratelow kilovolt

Identifiers

PMID34941641
PMCPMC8705800
OpenAlexW3216688914

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.