Evidence map›Paper›PMID 34940407›Full record

ArticleInfectious disease reports2021

A Sensitive, Portable Microfluidic Device for SARS-CoV-2 Detection from Self-Collected Saliva.

Jianing Yang, Mark Kidd, Alan R Nordquist, Stanley D Smith, Cedric Hurth, Irvin M Modlin, Frederic Zenhausern

Open access · goldAbstract read
In one paragraph

Article in Infectious disease reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.9field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Jianing YangCenter for Applied NanoBioscience and Medicine, College of Medicine-Phoenix, University of Arizona, Phoenix, AZ 85004, USA.
Mark KiddWREN Laboratories, Branford, CT 06405, USA.
Alan R NordquistCenter for Applied NanoBioscience and Medicine, College of Medicine-Phoenix, University of Arizona, Phoenix, AZ 85004, USA.
Stanley D SmithCenter for Applied NanoBioscience and Medicine, College of Medicine-Phoenix, University of Arizona, Phoenix, AZ 85004, USA.
Cedric HurthCenter for Applied NanoBioscience and Medicine, College of Medicine-Phoenix, University of Arizona, Phoenix, AZ 85004, USA.
Irvin M ModlinWREN Laboratories, Branford, CT 06405, USA.
Frederic ZenhausernCenter for Applied NanoBioscience and Medicine, College of Medicine-Phoenix, University of Arizona, Phoenix, AZ 85004, USA.ORCID 0000-0001-8360-9118
University of Arizona · USWren Laboratories (United States) · US

Funding

Costa Devices LLC UA-57677FX
6 · The paper itself

Abstract

Since the outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic in December 2019, the spread of SARS-CoV2 infection has been escalating rapidly around the world. In order to provide more timely access to medical intervention, including diagnostic tests and medical treatment, the FDA authorized multiple test protocols for diagnostic tests from nasopharyngeal swab, saliva, urine, bronchoalveolar lavage and fecal samples. The traditional diagnostic tests for this novel coronavirus 2019 require standard processes of viral RNA isolation, reverse transcription of RNA to cDNA, then real-time quantitative PCR with the RNA templates extracted from the patient samples. Recently, many reports have demonstrated a direct detection of SARS-Co-V2 genomic material from saliva samples without any RNA isolation step. To make the rapid detection of SARS-Co-V2 infection more accessible, a point-of-care type device was developed for SARS-CoV-2 detection. Herein, we report a portable microfluidic-based integrated detection-analysis system for SARS-CoV-2 nucleic acids detection directly from saliva samples. The saliva cartridge is self-contained and capable of microfluidic evaluation of saliva, from heating, mixing with the primers to multiplex real-time quantitative polymerase chain reaction, detecting SARS-CoV-2 with different primer sets and internal control. The approach has a detection sensitivity of 1000 copies/mL of SARS-CoV-2 RNA or virus, with consistency and automation, from saliva sample-in to result-out.

Indexed as

cartridgedetectionintegrationmicrofluidicssalivaSARS-CoV-2sensitivity

Identifiers

PMID34940407
PMCPMC8701218
OpenAlexW4200179418

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked