Evidence map›Paper›PMID 34940369›Full record

ArticleBioengineering (Basel, Switzerland)2021

The Interventricular Septum Is Biomechanically Distinct from the Ventricular Free Walls.

Michael Nguyen-Truong, Wenqiang Liu, Courtney Doherty, Kristen LeBar, Kevin M Labus, Christian M Puttlitz, Jeremiah Easley, Eric Monnet, Adam Chicco, Zhijie Wang

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Michael Nguyen-TruongSchool of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA.ORCID 0000-0002-1941-783X
Wenqiang LiuSchool of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA.ORCID 0000-0002-2323-7962
Courtney DohertySchool of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA.
Kristen LeBarDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.
Kevin M LabusDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.
Christian M PuttlitzSchool of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA.
Jeremiah EasleyDepartment of Clinical Sciences, Veterinary Teaching Hospital, Colorado State University, Fort Collins, CO 80523, USA.
Eric MonnetDepartment of Clinical Sciences, Veterinary Teaching Hospital, Colorado State University, Fort Collins, CO 80523, USA.
Adam ChiccoDepartment of Biomedical Sciences, Colorado State University, Fort Collins, CO 80523, USA.
Zhijie WangSchool of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA.ORCID 0000-0001-9551-516X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The interventricular septum contributes to the pumping function of both ventricles. However, unlike the ventricular wall, its mechanical behavior remains largely unknown. To fill the knowledge gap, this study aims to characterize the biaxial and transmural variation of the mechanical properties of the septum and compare it to the free walls of the left and right ventricles (LV/RV). Fresh hearts were obtained from healthy, adult sheep. The septal wall was sliced along the mid-line into two septal sides and compared to the epicardial layers of the LV- and RV-free walls. Biaxial tensile mechanical tests and constitutive modeling were performed to obtain the passive mechanical properties of the LV- and RV-side of the septum and ventricular walls. We found that both sides of the septum were significantly softer than the respective ventricular walls, and that the septum presented significantly less collagen than the ventricular walls. At low strains, we observed the symmetric distribution of the fiber orientations and a similar anisotropic behavior between the LV-side and RV-side of the septum, with a stiffer material property in the longitudinal direction, rather than the circumferential direction. At high strains, both sides showed isotropic behavior. Both septal sides had similar intrinsic elasticity, as evidenced by experimental data and constitutive modeling. These new findings offer important knowledge of the biomechanics of the septum wall, which may deepen the understanding of heart physiology.

Indexed as

complianceFung type modelovineseptaltransmural difference

Identifiers

PMID34940369
PMCPMC8698618

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.