Evidence map›Paper›PMID 34940273›Full record

ArticleBiosensors2021

On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients.

Sumin Bian, Ying Tao, Zhoule Zhu, Peixi Zhu, Qiqin Wang, Hemmings Wu, Mohamad Sawan

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Sumin BianCenBRAIN Labs, School of Engineering, Westlake University, Hangzhou 310024, China.ORCID 0000-0002-9470-8143
Ying TaoCollege of Pharmaceutical Sciences, Zhejiang University of Technology, Hangzhou 310014, China.ORCID 0000-0001-7284-5561
Zhoule ZhuDepartment of Neurosurgery, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, China.
Peixi ZhuCollege of Pharmaceutical Sciences, Zhejiang University of Technology, Hangzhou 310014, China.
Qiqin WangInstitute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China.
Hemmings WuDepartment of Neurosurgery, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, China.
Mohamad SawanCenBRAIN Labs, School of Engineering, Westlake University, Hangzhou 310024, China.ORCID 0000-0002-4137-7272
Second Affiliated Hospital of Zhejiang University · CNWestlake University · CNZhejiang University of Technology · CNJinan University · CN

Funding

National Natural Science Foundation of China 82104122Westlake University 10318A992001
6 · The paper itself

Abstract

On-site monitoring of carbamazepine (CBZ) that allows rapid, sensitive, automatic, and high-throughput detection directly from whole blood is of urgent demand in current clinical practice for precision medicine. Herein, we developed two types (being indirect vs. direct) of fiber-optic biolayer interferometry (FO-BLI) biosensors for on-site CBZ monitoring. The indirect FO-BLI biosensor preincubated samples with monoclonal antibodies towards CBZ (MA-CBZ), and the mixture competes with immobilized CBZ to bind towards MA-CBZ. The direct FO-BLI biosensor used sample CBZ and CBZ-horseradish peroxidase (CBZ-HRP) conjugate to directly compete for binding with immobilized MA-CBZ, followed by a metal precipitate 3,3'-diaminobenzidine to amplify the signals. Indirect FO-BLI detected CBZ within its therapeutic range and was regenerated up to 12 times with negligible baseline drift, but reported results in 25 min. However, Direct FO-BLI achieved CBZ detection in approximately 7.5 min, down to as low as 10 ng/mL, with good accuracy, specificity and negligible matric interference using a high-salt buffer. Validation of Direct FO-BLI using six paired sera and whole blood from epileptic patients showed excellent agreement with ultra-performance liquid chromatography. Being automated and able to achieve high throughput, Direct FO-BLI proved itself to be more effective for integration into the clinic by delivering CBZ values from whole blood within minutes.

Indexed as

Biosensing TechniquesEpilepsyCarbamazepineChromatography, LiquidHorseradish PeroxidaseHumansInterferometryCarbamazepineHorseradish Peroxidasebiosensorcarbamazepineepilepsyfiber-optic biolayer interferometrysignal enhancementwhole blood

Identifiers

PMID34940273
PMCPMC8699405
OpenAlexW4200621730

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.