ArticleBiosensors2021
Signal Enhancement in Oriented Immunosorbent Assays: A Balance between Accessibility of Antigen Binding Sites and Avidity.
Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 7 citations in OpenAlex.
- Glycoprotein biosensor boosted by signal amplification of heparin polysaccharide and insights into glycan-lectin recognition.Mikrochimica acta · 2026Article
- Oriented Antibody Coupling to an Antifouling Polymer Using Glycan Remodeling for Biosensing by Particle Motion.Bioconjugate chemistry · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The sensitivity of immunoassays was reported to be increased by the orientation of antibodies. We investigated how the size and valence of antigens and orientation and valence of antibodies contribute to the analytical sensitivity of ELISA. Antigens differing in size and number of epitopes were compared using oriented and non-oriented ELISAs: the orientation of antibodies was obtained coating half-fragment antibodies on maleimide microplates, while, in non-oriented ELISA, whole antibodies were randomly physisorbed. The oriented assay performed better than the non-oriented one at each concentration (0.4-3.3 ng/mL) of a small monomeric antigen (cardiac Troponin I, 24 kDa, Rh 3 nm). No significant differences were observed with a large monovalent antigen (prostate-specific antigen-alpha(1) antichymotrypsin, 90 kDa, Rh > 3 nm), since its steric hindrance overcame the increased availability of antigen binding sites given by orientation. Large multivalent antigens (ferritin, 280 kDa, Rh 6 nm; α-fetoprotein, >70 kDa, Rh > 3.3 nm) performed better in non-oriented assays. In this case, the repeated epitopes on the surface of the antigens favored the engagement of both antigen binding sites of the whole IgG, thus suggesting that avidity represented the leading force in this experimental setting. In conclusion, the design of high-sensitivity ELISAs should consider the dimension and valency of antigens in addition to the affinity and avidity of antibodies.