Evidence map›Paper›PMID 34940241›Full record

ArticleBiosensors2021

Quantitative, Temperature-Calibrated and Real-Time Glucose Biosensor Based on Symmetrical-Meandering-Type Resistor and Intertwined Capacitor Structure.

Yangchuan Ma, Tian Qiang, Minjia Gao, Junge Liang, Yanfeng Jiang

Abstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yangchuan MaDepartment of Electronic Engineering, School of Internet of Things Engineering, Jiangnan University, Wuxi 214122, China.
Tian QiangDepartment of Electronic Engineering, School of Internet of Things Engineering, Jiangnan University, Wuxi 214122, China.ORCID 0000-0002-4811-7094
Minjia GaoDepartment of Electronic Engineering, School of Internet of Things Engineering, Jiangnan University, Wuxi 214122, China.
Junge LiangDepartment of Electronic Engineering, School of Internet of Things Engineering, Jiangnan University, Wuxi 214122, China.
Yanfeng JiangDepartment of Electronic Engineering, School of Internet of Things Engineering, Jiangnan University, Wuxi 214122, China.

Funding

China Postdoctoral Science Foundation 2021M691284Fundamental Research Funds for the Central Universities JUSRP12026National Natural Science Foundation of China 61801146
6 · The paper itself

Abstract

Here, we propose a glucose biosensor with the advantages of quantification, excellent linearity, temperature-calibration function, and real-time detection based on a resistor and capacitor, in which the resistor works as a temperature sensor and the capacitor works as a biosensor. The resistor has a symmetrical meandering type structure that increases the contact area, leading to variations in resistance and effective temperature monitoring of a glucose solution. The capacitor is designed with an intertwined structure that fully contacts the glucose solution, so that capacitance is sensitively varied, and high sensitivity monitoring can be realized. Moreover, a polydimethylsiloxane microfluidic channel is applied to achieve a fixed shape, a fixed point, and quantitative measurements, which can eliminate influences caused by fluidity, shape, and thickness of the glucose sample. The glucose solution in a temperature range of 25-100 °C is measured with variations of 0.2716 Ω/°C and a linearity response of 0.9993, ensuring that the capacitor sensor can have reference temperature information before detecting the glucose concentration, achieving the purpose of temperature calibration. The proposed capacitor-based biosensor demonstrates sensitivities of 0.413 nF/mg·dL

Indexed as

Biosensing TechniquesGlucoseCalibrationElectric CapacitanceTemperatureGlucosebiosensorintertwined capacitormicrofluidic channelsymmetrical meandering type resistortemperature calibration

Identifiers

PMID34940241
PMCPMC8699495

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.