Exhaled Breath Analysis for Diabetes Diagnosis and Monitoring: Relevance, Challenges and Possibilities.

Kaushiki Dixit, Somayeh Fardindoost, Adithya Ravishankara, Nishat Tasnim, Mina Hoorfar

Open access · goldAbstract readReview
In one paragraph

Review in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed, 1 pooled it
6.9field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed, 1 synthesis or guideline pooled it, 113 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Observational
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Nanowire Array Breath Acetone Sensor for Diabetes Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  15. Review
  16. Article
  17. Comparison of CuJournal of the American Society for Mass Spectrometry · 2024
    Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 2 countries.

Kaushiki DixitDepartment of Electronics and Electrical Communication Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.
Somayeh FardindoostSchool of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada.ORCID 0000-0002-2904-0888
Adithya RavishankaraSchool of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada.
Nishat TasnimSchool of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada.ORCID 0000-0002-9899-2014
Mina HoorfarSchool of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada.
University of British Columbia · CA

Funding

Mitacs Globalink 2021Natural Sciences and Engineering Research Council NSERC CRD 522791-16 Hoorfar
6 · The paper itself

Abstract

With the global population prevalence of diabetes surpassing 463 million cases in 2019 and diabetes leading to millions of deaths each year, there is a critical need for feasible, rapid, and non-invasive methodologies for continuous blood glucose monitoring in contrast to the current procedures that are either invasive, complicated, or expensive. Breath analysis is a viable methodology for non-invasive diabetes management owing to its potential for multiple disease diagnoses, the nominal requirement of sample processing, and immense sample accessibility; however, the development of functional commercial sensors is challenging due to the low concentration of volatile organic compounds (VOCs) present in exhaled breath and the confounding factors influencing the exhaled breath profile. Given the complexity of the topic and the skyrocketing spread of diabetes, a multifarious review of exhaled breath analysis for diabetes monitoring is essential to track the technological progress in the field and comprehend the obstacles in developing a breath analysis-based diabetes management system. In this review, we consolidate the relevance of exhaled breath analysis through a critical assessment of current technologies and recent advancements in sensing methods to address the shortcomings associated with blood glucose monitoring. We provide a detailed assessment of the intricacies involved in the development of non-invasive diabetes monitoring devices. In addition, we spotlight the need to consider breath biomarker clusters as opposed to standalone biomarkers for the clinical applicability of exhaled breath monitoring. We present potential VOC clusters suitable for diabetes management and highlight the recent buildout of breath sensing methodologies, focusing on novel sensing materials and transduction mechanisms. Finally, we portray a multifaceted comparison of exhaled breath analysis for diabetes monitoring and highlight remaining challenges on the path to realizing breath analysis as a non-invasive healthcare approach.

Indexed as

Breath TestsDiabetes MellitusVolatile Organic CompoundsBiomarkersExhalationHumansBiomarkersVolatile Organic Compoundsbiomarkersblood glucose monitoringbreath sensordiabetesexhaled breath analysisnon-invasive detectionvolatile organic compounds

Identifiers

PMID34940233
PMCPMC8699302
OpenAlexW3217601412

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked