Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy.
Article in Biophysical reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Cationic Polyelectrolyte Adsorption onto Anionic Nanoparticles Analyzed with Frequency-Domain Scanning Fluorescence Correlation Spectroscopy.Small methods · 2025Article
- Array detection enables large localization range for simple and robust MINFLUX.Light, science & applications · 2025Article
- Wavefront estimation through structured detection in laser scanning microscopy.Biomedical optics express · 2025Article
- The role of RNA in the nanoscale organization of α-synuclein phase separation.NAR molecular medicine · 2025Article
- Structured detection for simultaneous super-resolution and optical sectioning in laser scanning microscopy.Nature photonics · 2025Article
- 4D Single-particle tracking with asynchronous read-out single-photon avalanche diode array detector.Nature communications · 2024Article
- Single-photon microscopy to study biomolecular condensates.Nature communications · 2023Article
- Super-resolution microscopy reveals the nanoscale cluster architecture of the DEK protein cancer biomarker.iScience · 2023Article
- Focus image scanning microscopy for sharp and gentle super-resolved microscopy.Nature communications · 2022Article
- The BrightEyes-TTM as an open-source time-tagging module for democratising single-photon microscopy.Nature communications · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The single-photon timing and sensitivity performance and the imaging ability of asynchronous-readout single-photon avalanche diode (SPAD) array detectors have opened up enormous perspectives in fluorescence (lifetime) laser scanning microscopy (FLSM), such as super-resolution image scanning microscopy and high-information content fluorescence fluctuation spectroscopy. However, the strengths of these FLSM techniques depend on the many different characteristics of the detector, such as dark noise, photon-detection efficiency, after-pulsing probability, and optical cross talk, whose overall optimization is typically a trade-off between these characteristics. To mitigate this trade-off, we present, to our knowledge, a novel SPAD array detector with an active cooling system that substantially reduces the dark noise without significantly deteriorating any other detector characteristics. In particular, we show that lowering the temperature of the sensor to -15°C significantly improves the signal/noise ratio due to a 10-fold decrease in the dark count rate compared with room temperature. As a result, for imaging, the laser power can be decreased by more than a factor of three, which is particularly beneficial for live-cell super-resolution imaging, as demonstrated in fixed and living cells expressing green-fluorescent-protein-tagged proteins. For fluorescence fluctuation spectroscopy, together with the benefit of the reduced laser power, we show that cooling the detector is necessary to remove artifacts in the correlation function, such as spurious negative correlations observed in the hot elements of the detector, i.e., elements for which dark noise is substantially higher than the median value. Overall, this detector represents a further step toward the integration of SPAD array detectors in any FLSM system.