ArticlePlastic and reconstructive surgery. Global open2021
Fingerstall-type Tissue Oximetry Reduced Anxiety of Nurses in Postoperative Nursing Monitoring of Free Flaps.
Article in Plastic and reconstructive surgery. Global open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Nurse-Led Microsurgical Free Flap Monitoring: A Scoping Review and Evidence-Based Framework.Healthcare (Basel, Switzerland) · 2025Review
- A novel device to assess the oxygen saturation and congestion status of the gastric conduit in thoracic esophagectomy.BMC surgery · 2024Article
- Erratum: Fingerstall-type Tissue Oximetry Reduced Anxiety of Nurses in Postoperative Nursing Monitoring of Free Flaps: Erratum.Plastic and reconstructive surgery. Global open · 2022Article
Corrections and comments
- Erratum issued
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Postoperative free flap monitoring is essential for immediately detecting obstruction of anastomosed vessels with successive recovery surgery for salvaging flaps. We performed postoperative nursing monitoring using handheld Doppler sonography, but nurses reported feeling anxious with this approach and demanded a clear-cut evaluation method. Therefore, we implemented monitoring with the fingerstall-type tissue oximeter Toccare, a noninvasive device that enables easy flap checking by simply touching the flap with a probe.
methodHandheld Doppler was used for nursing monitoring from April to October 2020, with anxiety associated with its use reported. We collected information via an anonymous questionnaire to determine the reason for the anxiety. Toccare was subsequently applied for postoperative free flap monitoring by nurses. The protocol involved measuring tissue oxygen saturation by touching the flap with a Toccare probe every 4 hours from 24 to 100 hours postoperatively. Seven months later, a second anonymous questionnaire was conducted, and results were compared.
resultFree deep inferior epigastric artery perforator flaps and anterolateral thigh flaps (n = 5 each) were included. The average tissue oxygen saturation values in the deep inferior epigastric artery perforator and anterolateral thigh flaps were 52.0% and 52.4%, respectively. According to the second questionnaire about Toccare, 7% felt anxious, 62% felt slightly anxious, and 31% did not feel anxious. Toccare was preferred by 89% of nurses who had used both methods.
conclusionsFlap monitoring using Toccare reduced nurses' anxiety. A numerical evaluation method with easy handling and clear doctor call criteria is essential for low-anxiety nursing monitoring.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.