Observational studyClinical neuroradiology2022
Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke.
Observational study in Clinical neuroradiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 10 citations in OpenAlex.
- Stent retrievers for acute ischemic stroke: technological advances, clinical applications, and future perspectives.Journal of neurology · 2026Review
- Real-world experience of the large 6 × 50 mm Aperio Stent-retriever: evaluation of effectiveness and safety.Neuroradiology · 2026Article
- Safety, Technical and Clinical Success of the Aperio Hybrid Thrombectomy Device in Acute Ischemic Stroke, a Prospective Post-market Clinical Follow-up Study (HYBRID).Clinical neuroradiology · 2026Article
- Innovation and development of stent retrievers in acute ischemic stroke.Frontiers of medicine · 2025Review
- Comparison of the Aperio HybridInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Thrombectomy for Anterior Circulation Stroke with a Hybrid Cell Design Stent Retriever: A Multicenter Registry.Journal of neuroendovascular therapy · 2025Article
- A prospective, multicentre, registry study of RECO in the endovascular treatment of acute ischaemic stroke.Scientific reports · 2024Article
- In Vitro Analysis of the Efficacy of Endovascular Thrombectomy Techniques according to the Vascular Tortuosity Using 3D Printed Models.AJNR. American journal of neuroradiology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIt is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness.
methodsObservational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retriever device (01/2019-09/2020) for mechanical thrombectomy (MT) in large vessel occlusion (LVO) stroke. Primary effectiveness endpoint was successful recanalization eTICI (expanded Thrombolysis In Cerebral Ischemia) ≥ 2b67, primary safety endpoint was occurrence of hemorrhagic complications after MT. Secondary outcome measures were time from groin puncture to first pass and successful reperfusion, and the total number of passes needed to achieve the final recanalization result.
resultsA total of 298 patients with LVO stroke who were treated by MT matched the inclusion criteria: 148 patients (49.7%) treated with AP vs. 150 patients (50.3%) treated with new generation APH. Successful recanalization was not statistically different between both groups: 75.7% for AP vs. 79.3% for APH; p = 0.450. Postinterventional hemorrhagic complications and particularly subarachnoid hemorrhage as the entity possibly associated with stent-retriever device type was significantly less frequent in the group treated with the APH: 29.7% for AP and 16.0% for APH; p = 0.005; however, rates of symptomatic hemorrhage with clinical deterioration and in domo mortality were not statistically different. Neither the median number of stent-retriever passages needed to achieve final recanalization, time from groin puncture to first pass, time from groin puncture to final recanalization nor the number of cases in which successful recanalization could only be achieved by using a different stent-retriever as bail-out device differed between both groups.
conclusionIn the specific example of the APERIO® stent-retriever device, we observed that further technological developments of the new generation device were not associated with disadvantages with respect to typical observational indicators of safety or effectiveness.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials