Differences in image density adjustment parameters on the image matching accuracy of a floor-mounted kV X-ray image-guided radiation therapy system.

Kanako Sakuragawa, Motoharu Sasaki, Takeshi Kamomae, Michihiro Yokoishi, Ryosuke Kasai, Akimi Kajino, Hitoshi Ikushima

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kanako SakuragawaDepartment of Radiological Technology, Tokushima University Hospital, Tokushima, 770-8503, Japan.
Motoharu SasakiDepartment of Therapeutic Radiology Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, 770-8503, Japan.
Takeshi KamomaeDepartment of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, 466-8550, Japan.
Michihiro YokoishiDepartment of Radiological Technology, Tokushima University Hospital, Tokushima, 770-8503, Japan.
Ryosuke KasaiDepartment of Radiological Technology, Tokushima University Hospital, Tokushima, 770-8503, Japan.ORCID https://orcid.org/0000-0002-4699-1642
Akimi KajinoGraduate School of Health Sciences, Tokushima University, Tokushima, 770-8503, Japan.
Hitoshi IkushimaDepartment of Therapeutic Radiology Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, 770-8503, Japan.ORCID https://orcid.org/0000-0003-1578-4293

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to investigate the effect of two different image density adjustment parameters on the results of image matching at six degrees of freedom using radiographic images generated by the ExacTrac X-ray system in brain stereotactic radiosurgery (SRS). This study comprised 32 patients who underwent brain SRS at our hospital from January 2020 to December 2020. In this study, (1) the default parameter (an image density parameter between "tissue" and "bone") was an image density parameter for digitally reconstructed radiograph (DRR) generation used at many facilities, and (2) the bone parameter was the steepest contrast parameter used at our hospital. Of the 32 patients, 24 (75%) had a couch angle of 0.5 mm or more in the translational direction or 0.5° or more in the rotational direction, and 10 (31%) had a couch angle of 1.0 mm or more in the translational direction or 1.0° or more in the rotational direction. Among the 131 cases of all couch angles, 46 (35%) cases had a translational direction of 0.5 mm or more or a rotational direction of 0.5° or more, and 15 (11%) had a translational direction of 1.0 mm or more or a rotational direction of 1.0° or more. The results of this study indicate the usefulness of using appropriate DRR parameters for each case, rather than using the default settings. The use of appropriate DRR parameters can lead to accurate position matching results, leading to fewer image-guided radiation therapy shots and a lower imaging dose.

Indexed as

RadiosurgeryRadiotherapy, Image-GuidedCone-Beam Computed TomographyHumansRadiographyRadiotherapy Planning, Computer-AssistedX-Raysbrain metastasisdigitally reconstructed radiographExacTracstereotactic radiosurgery

Identifiers

PMID34931431
PMCPMC8833277

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.