Evidence map›Paper›PMID 34931299›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

VR-based training of craniotomy for intracranial aneurysm surgery.

Mareen Allgaier, Amir Amini, Belal Neyazi, I Erol Sandalcioglu, Bernhard Preim, Sylvia Saalfeld

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.1field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. New horizons in dermatological education: Skin cancer screening with virtual reality.Journal of the European Academy of Dermatology and Venereology : JEADV · 2024
    Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Mareen AllgaierFaculty of Computer Science, Otto-von-Guericke University Magdeburg, Universitätsplatz 2, 39106, Magdeburg, Germany. mareen.allgaier@isg.cs.ovgu.de.ORCID http://orcid.org/0000-0002-7099-4819
Amir AminiUniversity Hospital Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany.ORCID http://orcid.org/0000-0001-8360-9046
Belal NeyaziUniversity Hospital Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany.ORCID http://orcid.org/0000-0002-3163-0545
I Erol SandalciogluUniversity Hospital Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany.ORCID http://orcid.org/0000-0002-8922-2616
Bernhard PreimFaculty of Computer Science, Otto-von-Guericke University Magdeburg, Universitätsplatz 2, 39106, Magdeburg, Germany.ORCID http://orcid.org/0000-0001-9826-9478
Sylvia SaalfeldFaculty of Computer Science, Otto-von-Guericke University Magdeburg, Universitätsplatz 2, 39106, Magdeburg, Germany.ORCID http://orcid.org/0000-0002-7002-7917
Otto-von-Guericke-Universität Magdeburg · DEUniversity Hospital Magdeburg · DE

Funding

bundesministerium für bildung und forschung 13GW0473Adeutsche forschungsgemeinschaft SA 3461/2-1
6 · The paper itself

Abstract

purposeIntracranial aneurysms can be treated micro-surgically. This procedure involves an appropriate head position of the patient and a proper craniotomy. These steps enable a proper access, facilitating the subsequent steps. To train the access planning process, we propose a VR-based training system.

methodWe designed and implemented an immersive VR access simulation, where the user is surrounded by a virtual operating room, including medical equipment and virtual staff. The patient's head can be positioned via hand rotation and an arbitrary craniotomy contour can be drawn. The chosen access can be evaluated by exposing the aneurysm using a microscopic view.

resultsThe evaluation of the simulation took place in three stages: testing the simulation using the think-aloud method, conducting a survey and examining the precision of drawing the contour. Although there are differences between the virtual interactions and their counterparts in reality, the participants liked the immersion and felt present in the operating room. The calculated surface dice similarity coefficient, Hausdorff distance and feedback of the participants show that the difficulty of drawing the craniotomy is appropriate.

conclusionThe presented training simulation for head positioning and access planning benefits from the immersive environment. Thus, it is an appropriate training for novice neurosurgeons and medical students with the goal to improve anatomical understanding and to become aware of the importance of the right craniotomy hole.

Indexed as

Intracranial AneurysmSimulation TrainingVirtual RealityComputer SimulationCraniotomyFeedbackHumansCraniotomyIntracranial aneurysmSurgical trainingVirtual reality

Identifiers

PMID34931299
PMCPMC8873137
OpenAlexW4200472095

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.