Evidence map›Paper›PMID 34930185›Full record

ArticleBMC musculoskeletal disorders2021

Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study.

Amirhossein Borjali, Amir Nourani, Hadi Moeinnia, Mahdi Mohseni, Hossein Korani, Narges Ghias, Mahmoud Chizari

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Sheathed fixation improves BASHTI technique in an anterior cruciate ligament reconstruction.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2023
    Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Amirhossein BorjaliDepartment of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
Amir NouraniDepartment of Mechanical Engineering, Sharif University of Technology, Tehran, Iran. nourani@sharif.edu.
Hadi MoeinniaDepartment of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
Mahdi MohseniDepartment of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
Hossein KoraniSchool of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran.
Narges GhiasDepartment of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
Mahmoud ChizariDepartment of Engineering and Technology, University of Hertfordshire, College Lane Campus, Hatfield, AL10 9AB, UK. m.chizari@herts.ac.uk.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBone and Site Hold Tendon Inside (BASHTI) technique is an organic implant-less technique for anterior cruciate ligament (ACL) reconstruction with some clinical advantages, such as speeding up the healing process, over implantable techniques. The study aims to compare the mechanical properties of BASHTI technique with the conventional interference screw technique.

methodsTo investigate the mechanical properties, 20 in-vitro experimental tests were conducted. Synthetic dummy bone, along with fresh digital bovine tendons, as a graft, were used for experiments. Three loading steps were applied to all specimens, including a preconditioning, a main cyclic, and a pull-out loading.

resultsThe mechanical characters of an interference screw technique using an 8 mm tendon diameter, including fixation strength, average cyclic stiffness (ACS), and average pull-out stiffness (APS) were found to be 439 ± 132 N, 10.3 ± 5.3 kN/mm, and 109 ± 40 N/mm, respectively. In the case of an interference screw using a 9 mm tendon, the fixation strength, ACS, and APS were obtained 549 ± 87 N, 10.3 ± 4.7 kN/mm, and 91 ± 13 N/mm, respectively. In parallel, the fixation strength, APS, and ACS of BASHTI technique using an 8 mm tendon were 360 ± 123 N, 3.3 ± 0.6 kN/mm, and 79 ± 27 N/mm, respectively, while, for 9 mm tendon 278 ± 103 N, 2.4 ± 1.2 kN/mm, and 111 ± 40 N/mm, were reported for fixation strength, APS, and ACS respectively when BASHTI technique was used.

conclusionAbout 50% of interference screw samples showed superior mechanical properties compared to BASHTI technique, but in another half of the samples, the differences were not significant (N.S.). However, due to organic advantages of BASHTI technique and lower cost, it could be used as a substitute for interference screw technique, especially where fast recovery is expected.

Indexed as

Anterior Cruciate Ligament ReconstructionAnimalsBone ScrewsCattleHumansACL reconstructionBASHTI techniqueCore boneImplant-lessInterference screwTensile test

Identifiers

PMID34930185
PMCPMC8691038

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.