Evidence map›Paper›PMID 34930137›Full record

Observational studyBMC anesthesiology2021

LMA® protector™ in patients undergoing laparoscopic surgeries: a multicenter prospective observational study.

Yanhong Liu, Yuxiang Song, Miaomiao Wang, Meihua Yang, Hao Shen, Zhen Wang, Liyong Chen, Jianjun Yang, Shengkai Gong, Yonghao Yu and 8 more

Registry-linked trialOpen access · goldAbstract readMulticenter StudyObservational Study
In one paragraph

Observational study in BMC anesthesiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06527352 (Comparison of Risk of Gastroesophageal Reflux During General Anesthesia With Tulip vs GMA), which is not on this map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06527352 nacompletednot on this mapstarted 2024, after this paper: background citation

Comparison of Risk of Gastroesophageal Reflux During General Anesthesia With Tulip vs GMA(Glottis Mask Airway) Airway

TypeinterventionalSponsorAir Force Military Medical University, ChinaRan2024 to 2025Enrolled72ConditionsAnesthesiaArmsglottis mask airway, tulip shaped, classical shaped
3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 16 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors at 7 institutions in 1 country.

Yanhong Liu *Department of Anesthesiology, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
Yuxiang Song *Department of Anesthesiology, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
Miaomiao WangDepartment of Anesthesiology, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
Meihua YangDepartment of Anesthesiology, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
Hao ShenDepartment of Anesthesiology, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
Zhen WangDepartment of Anesthesiology, Daping Hospital, Army Medical University, Chongqing, China.
Liyong ChenDepartment of Anesthesiology, Daping Hospital, Army Medical University, Chongqing, China.
Jianjun YangDepartment of Anesthesiology and Perioperative Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Shengkai GongDepartment of Anesthesiology and Perioperative Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Yonghao YuDepartment of Anesthesiology, Tianjin Medical University General Hospital, Tianjin, China.
Zhao ShiDepartment of Anesthesiology, Tianjin Medical University General Hospital, Tianjin, China.
Wei ZhangDepartment of Anesthesiology and Perioperative Medicine, Henan Provincial People's Hospital, Zhengzhou, China.
Xuli ZouDepartment of Anesthesiology and Perioperative Medicine, Henan Provincial People's Hospital, Zhengzhou, China.
Xude SunDepartment of Anesthesiology, The Second Affiliated Hospital of Air Force Medical University, Xi'an, China.
Yuan WangDepartment of Anesthesiology, The Second Affiliated Hospital of Air Force Medical University, Xi'an, China.
Qiang FuDepartment of Anesthesiology, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
Jiangbei CaoDepartment of Anesthesiology, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
Weidong MiDepartment of Anesthesiology, The First Medical Center of Chinese PLA General Hospital, Beijing, China. wwdd1962@aliyun.com.
Chinese PLA General Hospital · CNAir Force Medical University · CNArmy Medical University · CNFirst Affiliated Hospital of Zhengzhou University · CNHenan Provincial People's Hospital · CNTianjin Medical University General Hospital · CNPLA Academy of Military Science · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLaryngeal masks airway (LMA) has been increasingly used in surgical patients. However, the use of LMA in laparoscopic surgeries remains controversial. The major concerns include the potential risk of esophageal regurgitation, aspiration, and difficulties to achieve effective ventilation. The aim of this study was to evaluate the safety and effectiveness of the LMA® Protector™ in patients undergoing laparoscopic surgery.

methodsPatients aged 18 to 70 years, scheduled for laparoscopic surgeries were included. The insertion time, successful insertion rate, and oropharyngeal leak pressure were measured. Airway complications and airway manipulations during the procedure were documented. Effective ventilation rate was calculated. Visible bloodstains and reflux content in the drainage channel were documented after the removal of LMA® Protector™.

resultsThree hundred patients were enrolled. The insertion of LMA® Protector™ failed in seven patients resulting with a successful insertion rate of 97.7%. During the maintenance of anesthesia, airway manipulation was required in 19 patients (19/293, 6.48%), in three of whom the LMA was replaced with endotracheal intubation resulting with an effective ventilation rate of 96.7% (290/300). The oropharyngeal leak pressure was 30.18 ± 5.88 cmH

conclusionsThe LMA® Protector™ was shown to be safe and effective in patients undergoing laparoscopic surgeries. Although minor complications that require no further treatment, no clinically diagnosed aspiration was noticed in our study. Gastric reflux was noticed in the drainage tube in five patients undergoing laparoscopic gynecology surgery. Further research is needed to verify whether LMA® Protector™ is suitable for procedures in Trendelenburg position or other situations that a high risk of gastroesophageal reflux exists.

trial registrationThe trial was registered at the Chinese Clinical Trial Registry ( ChiCTR1800018300 , date of registration: September 2018).

Indexed as

LaparoscopyLaryngeal MasksAdolescentAdultAgedEquipment DesignFemaleHumansMaleMiddle AgedPatient PositioningProspective StudiesYoung AdultAirway managementLaparoscopyLaryngeal masksSupraglottic airway device

Identifiers

PMID34930137
PMCPMC8686540
OpenAlexW4226198308

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.