Trial reportThe Laryngoscope2022
Pharyngo-Esophageal Modulatory Swallow Responses to Bolus Volume and Viscosity Across Time.
Trial report in The Laryngoscope, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 13 citations in OpenAlex.
- Effects of the GABA(B) agonist baclofen on volitional swallowing in normal subjects.The Kaohsiung journal of medical sciences · 2023Trial
- Effects of dexmedetomidine on pharyngeal swallowing and esophageal motility-A double-blind randomized cross-over study in healthy volunteers.Neurogastroenterology and motility · 2023Trial
- Impact of expiratory muscle strength training on swallowing function in Parkinson's disease: insights from high-resolution videomanometry.Clinics (Sao Paulo, Brazil) · 2026Article
- The Influence of Liquid Consistency and Food Texture on Swallowing: A Systematic Review Update.Dysphagia · 2026Review
- Effects of Aging on Correlation of Striated Esophageal and Pharyngeal Deglutitive Motor Function.Gastroenterology research and practice · 2026Article
- A Machine Learning Pipeline for Automated Bolus Segmentation and Area Measurement in Swallowing Videofluoroscopy Images of an Infant Pig Model.Dysphagia · 2025Article
- Correlation Between Peak Upper Esophageal Sphincter and Pharyngeal Pressures in Patients With Dysphagia.Laryngoscope investigative otolaryngology · 2025Article
- Effect of Thickened Fluids on Swallowing Function in Oropharyngeal Dysphagia: Impact of Shear Rheology and Disorder Subtype.Neurogastroenterology and motility · 2025Article
- Post-stroke dysphagia: identifying the evidence missing.Frontiers in medicine · 2025Review
- Pharyngeal adaptation to bolus properties in patients with Parkinson's disease.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024Article
- Normal Variations in Upper Esophageal Sphincter Function During Deglutition: A Secondary Analysis of Videofluoroscopic Data.The Laryngoscope · 2024Article
- Upper Esophageal Sphincter Metrics across Eosinophilic Esophagitis, Gastroesophageal Reflux Disease and Functional Dysphagia: A Pilot Study.Journal of clinical medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectives/hypothesisModulation of the pharyngeal swallow to bolus volume and viscosity is important for safe swallowing and is commonly studied using high-resolution pharyngeal manometry (HRPM). Use of unidirectional pressure sensor technology may, however, introduce variability in swallow measures and a fixed bolus administration protocol may induce time and order effects. We aimed to overcome these limitations and to investigate the effect of time by repeating randomized measurements using circumferential pressure sensor technology. STUDY
designSub-set analysis of data from the placebo arm of a randomized, repeated measures trial.
methodsHRPM with impedance was recorded using a solid-state catheter with 36 circumferential pressure sensors and 18 impedance segments straddling from hypopharynx to stomach. Testing included triplicates of 5, 10, and 20 ml thin liquid and 10 ml thick liquid boluses, the order of the thin liquid boluses was randomized. The swallow challenges were repeated approximately 10 minutes after finishing the baseline measurement.
resultsWe included 19 healthy adults (10/9 male/female; age 24.5 ± 4.1 year). Intrabolus pressure, all upper esophageal sphincter (UES) opening and relaxation metrics, and flow timing metrics increased with larger volumes. A thicker viscosity decreased UES relaxation time, UES basal pressure, and flow timing metrics, whereas UES opening extent increased. Pre-swallow UES basal pressure and post-swallow UES contractile integral decreased over time.
conclusionUsing circumferential pressure sensor technology, the effects of volume and viscosity were largely consistent with previous reports. UES contractile pressures reduced over time. The growing body of literature offers a benchmark for recognizing aberrant pharyngo-esophageal motor responses. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:1817-1824, 2022.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials