ArticleTransfusion2022
Acquired platelet storage container leaks and contamination with environmental bacteria: A preventable cause of bacterial sepsis.
Article in Transfusion, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 19 citations in OpenAlex.
- Assessment of the efficacy of large volume delayed sampling primary culture and pathogen reduction in preventing septic reactions from platelet transfusions.Transfusion · 2026Review
- Consideration in Platelet Transfusion-Transmitted Klebsiella pneumoniae Sepsis: A Case Report.Cureus · 2026Article
- Review
- Alterations in RNA Expression Profile FollowingInternational journal of molecular sciences · 2025Article
- Growth and Distribution of Bacteria in Contaminated Whole Blood and Derived Blood Components.Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie · 2024Article
- Bacterial Contamination of Platelet Products.Microorganisms · 2024Review
- Septic Transfusion Reactions InvolvingMicroorganisms · 2023Review
- Posttransfusion sepsis attributable to bacterial contamination in platelet collection set manufacturing, United States.Transfusion · 2023Article
- Posttransfusion Sepsis Attributable to Bacterial Contamination in Platelet Collection Set Manufacturing Facility, United States.Emerging infectious diseases · 2023Review
- Platelet components and bacterial contamination: hospital perspective 2022.Hematology. American Society of Hematology. Education Program · 2022Article
- Acquired platelet storage container leaks and contamination with environmental bacteria: A preventable cause of bacterial sepsis.Transfusion · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundApheresis platelets (AP) may be contaminated by environmental bacteria via container defects acquired during processing, transport, storage, or transfusion, as highlighted by a recent series of septic reactions related to Acinetobacter spp. and other bacterial strains. STUDY DESIGN AND
methodsThe frequency and nature of acquired container defect reports to one manufacturer were evaluated from January 2019 to July 2020. The published incidence of contamination and sepsis due to environmental bacteria with culture screened AP in the United States was reviewed for the period of 2010-2019.
resultsReview of a manufacturers' records showed 23 US reports of leaks involving 24 containers attributed to postmanufacturing damage, at a rate of 44 per million distributed storage containers. Analysis of returned containers showed evidence of scratches, impressions, and/or piercings. Literature review of US hemovigilance data revealed that environmental bacteria comprised 7% of confirmed positive primary bacterial culture screens, were responsible for 14%-16% of reported septic, and 8 of 28 (29%) fatal reactions with bacterial-culture screened AP. Sepsis cases have been reported with culture screened, point-of-issue (POI) tested, or pathogen-reduced AP. DISCUSSION: Environmental contamination of AP is rare but can cause sepsis. Container damage provides a pathway for contamination after culture screening, POI bacteria testing, or pathogen reduction. Blood collectors and transfusion services should have procedures to ensure proper inspection, handling, storage, and transport of AP to avoid damage and should enhance efforts to detect defects prior to release and to eliminate bacteria from all contacting surfaces to minimize the risk of contamination.