Evidence map›Paper›PMID 34925931›Full record

ArticleCase reports in surgery2021

Patient-Matched 3-D-Printed Guides for the Insertion of Cervical Pedicle Screws in Tumor Surgery.

C-E Heyde, G Osterhoff, Spiegl Uja, A Völker, N H von der Höh, J S Jarvers

Open access · goldAbstract readCase Reports
In one paragraph

Article in Case reports in surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

C-E HeydeSpine Division, Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103 Leipzig, Germany.
G OsterhoffSpine Division, Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103 Leipzig, Germany.ORCID https://orcid.org/0000-0001-5051-0998
Spiegl UjaSpine Division, Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103 Leipzig, Germany.
A VölkerSpine Division, Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103 Leipzig, Germany.
N H von der HöhSpine Division, Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103 Leipzig, Germany.
J S JarversSpine Division, Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103 Leipzig, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPedicle screw fixation in the cervical spine provides biomechanical advantages compared to other stabilization techniques. However, pedicle screw insertion in this area is challenging due to the anatomical conditions with a high risk of breaching the small pedicles and violating the vertebral artery or neural structures. Today, several techniques to facilitate screw insertion and to make the procedure safer are used. 3-D-printed patient-matched guides based on a CT reconstruction are a helpful technique which allows to reduce operation time and to improve the safety of pedicle screw insertion at the cervical spine. CASES: 3-D-printed patient-matched drill guides based on a CT scan with a 3-D reconstruction of the spine were used in two challenging cervical spine surgical tumor cases to facilitate the implantation of the pedicle screws. The screw position was controlled postoperatively by means of the routinely performed CT scan.

resultsPostoperative imaging (conventional radiographs and CT scan) revealed the correct position of the pedicle screws. The time needed for screw insertion was short, and the need for intraoperative fluoroscopy could be reduced. There was no intra- or postoperative complication related to the pedicle screw implantation. Both tumors could be removed completely.

conclusionThese preliminary results show that 3-D-printed patient-specific guides are a promising tool to support and facilitate the implantation of cervical pedicle screws. The time needed for insertion is short, and intraoperative fluoroscopy time can be reduced. This technique allows for both a meticulous preoperative planning and a correct and therefore safe intraoperative positioning of cervical spine pedicle screws.

Identifiers

PMID34925931
PMCPMC8678078
OpenAlexW3216896816

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.