Evidence map›Paper›PMID 34916610›Full record

ArticleNature biomedical engineering2022

Chronic electrical stimulation of peripheral nerves via deep-red light transduced by an implanted organic photocapacitor.

Malin Silverå Ejneby, Marie Jakešová, Jose J Ferrero, Ludovico Migliaccio, Ihor Sahalianov, Zifang Zhao, Magnus Berggren, Dion Khodagholy, Vedran Đerek, Jennifer N Gelinas and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Nature biomedical engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 58 papers.

0numbers the graph read from it
0cells of the map it votes in
58citing papers in PubMed
9.5field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

58 citing papers in PubMed, 141 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Implantable bioelectronic outlet.Science advances · 2026
    Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. A self-wrapping, bioresorbable neural interface for wireless multimodal therapy of localized peripheral nerve injury.Proceedings of the National Academy of Sciences of the United States of America · 2026
    Article
  11. Article
  12. Autonomous Implants.Advanced materials (Deerfield Beach, Fla.) · 2025
    Review
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 5 countries.

Malin Silverå Ejneby *Laboratory of Organic Electronics, Campus Norrköping, Linköping University, Norrköping, Sweden.
Marie Jakešová *Laboratory of Organic Electronics, Campus Norrköping, Linköping University, Norrköping, Sweden.
Jose J Ferrero *Institute for Genomic Medicine, Columbia University Medical Center, New York, NY, USA.
Ludovico Migliaccio *Laboratory of Organic Electronics, Campus Norrköping, Linköping University, Norrköping, Sweden.
Ihor SahalianovLaboratory of Organic Electronics, Campus Norrköping, Linköping University, Norrköping, Sweden.
Zifang ZhaoDepartment of Electrical Engineering, Columbia University, New York, NY, USA.ORCID http://orcid.org/0000-0003-4145-4562
Magnus BerggrenLaboratory of Organic Electronics, Campus Norrköping, Linköping University, Norrköping, Sweden.
Dion KhodagholyDepartment of Electrical Engineering, Columbia University, New York, NY, USA.ORCID http://orcid.org/0000-0003-0805-4612
Vedran ĐerekLaboratory of Organic Electronics, Campus Norrköping, Linköping University, Norrköping, Sweden. vdjerek@phy.hr.ORCID http://orcid.org/0000-0001-9507-6865
Jennifer N GelinasInstitute for Genomic Medicine, Columbia University Medical Center, New York, NY, USA. jng2146@cumc.columbia.edu.ORCID http://orcid.org/0000-0002-1164-638X
Eric Daniel GłowackiLaboratory of Organic Electronics, Campus Norrköping, Linköping University, Norrköping, Sweden. eric.daniel.glowacki@ceitec.vutbr.cz.ORCID http://orcid.org/0000-0002-0280-8017
Linköping University · SEColumbia University · USColumbia University Irving Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Implantable devices for the wireless modulation of neural tissue need to be designed for reliability, safety and reduced invasiveness. Here we report chronic electrical stimulation of the sciatic nerve in rats by an implanted organic electrolytic photocapacitor that transduces deep-red light into electrical signals. The photocapacitor relies on commercially available semiconducting non-toxic pigments and is integrated in a conformable 0.1-mm

Indexed as

Prostheses and ImplantsSciatic NerveAnimalsElectric StimulationRatsReproducibility of Results

Identifiers

PMID34916610
OpenAlexW4200398495

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.