Classification of X-Ray Attenuation Properties of Additive Manufacturing and 3D Printing Materials Using Computed Tomography From 70 to 140 kVp.

Xiangjie Ma, Martin Buschmann, Ewald Unger, Peter Homolka

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Comparison and calibration of dose delivered byPhysics in medicine and biology · 2022
    Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Xiangjie MaCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Martin BuschmannDivision of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Ewald UngerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Peter HomolkaCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Additive manufacturing and 3D printing is particularly useful in the production of phantoms for medical imaging applications including determination and optimization of (diagnostic) image quality and dosimetry. Additive manufacturing allows the leap from simple slab and stylized to (pseudo)-anthropomorphic phantoms. This necessitates the use of materials with x-ray attenuation as close as possible to that of the tissues or organs mimicked. X-ray attenuation properties including their energy dependence were determined for 35 printing materials comprising photocured resins and thermoplastic polymers. Prior to measuring x-ray attenuation in CT from 70 to 140 kVp, printing parameters were thoroughly optimized to ensure maximum density avoiding too low attenuation due to microscopic or macroscopic voids. These optimized parameters are made available. CT scanning was performed in a water filled phantom to guarantee defined scan conditions and accurate HU value determination. The spectrum of HU values covered by polymers printed using fused deposition modeling reached from -258 to +1,063 at 120 kVp (-197 to +1,804 at 70 kVp, to -266 to +985 at 140 kVp, respectively). Photocured resins covered 43 to 175 HU at 120 kVp (16-156 at 70, and 57-178 at 140 kVp). At 120 kVp, ASA mimics water almost perfectly (+2 HU). HIPS (-40 HU) is found close to adipose tissue. In all photocurable resins, and 17 printing filaments HU values decreased with increasing beam hardness contrary to soft tissues except adipose tissue making it difficult to mimic water or average soft tissue in phantoms correctly over a range of energies with one single printing material. Filled filaments provided both, the HU range, and an appropriate energy dependence mimicking bone tissues. A filled material with almost constant HU values was identified potentially allowing mimicking soft tissues by reducing density using controlled under-filling. The measurements performed in this study can be used to design phantoms with a wide range of x-ray contrasts, and energy dependence of these contrasts by combining appropriate materials. Data provided on the energy dependence can also be used to correct contrast or contrast to noise ratios from phantom measurements to real tissue contrasts or CNRs.

Indexed as

3D printingadditive manufacturingcomputed tomographyphantom materialsquality controlradiographic phantomsx-ray

Identifiers

PMID34912790
PMCPMC8666890

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.