ArticleJournal of applied biomedicine2021
Finite element analysis of the tibial component alignment in a transverse plane in total knee arthroplasty.
Article in Journal of applied biomedicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The research aims to analyze the tibial component rotation using the finite element method by resecting the tibia in a transverse plane at an angle between 1.5° (external rotation) and -1.5° (internal rotation). We used a three-dimensional scanner to obtain the tibia's geometrical model of a cadaveric specimen. We then exported the surfaces of the tibial geometrical model through the Computer-Aided Three-dimensional Interactive Application (CATIA), which is a Computer-Aided Design (CAD) program. The CAD program three-dimensionally shaped the tibial component, polyethylene, and cement. Our analysis determined that the maximum equivalent stress is obtained in the case of proximal tibial resection at -1.5° angle in a transverse plane (internal rotation) with a value of 12.75 MPa, which is also obtained for the polyethylene (7.693 MPa) and cement (6.6 MPa). The results have shown that detrimental effects begin to occur at -1.5°. We propose the use of this finite element method to simulate the positioning of the tibial component at different tibial resection angles to appreciate the optimal rotation.
Indexed as
Identifiers
34907743What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.