Evidence map›Paper›PMID 34905066›Full record

ArticleArchives of orthopaedic and trauma surgery2023

Impaction bone grafting for segmental acetabular defects: a biomechanical study.

Wagener Nele, Fritsch Martina, Reinicke Stefan, Layher Frank, Matziolis Georg

Open access · hybridAbstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Wagener NeleDepartment of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center Göttingen, Georg-August-University, Robert Koch Straße 40, 37075, Göttingen, Germany. nele.wagener@med.uni-goettingen.de.ORCID http://orcid.org/0000-0002-4012-1363
Fritsch MartinaOrthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, 07607, Eisenberg, Germany.
Reinicke StefanOrthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, 07607, Eisenberg, Germany.
Layher FrankOrthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, 07607, Eisenberg, Germany.
Matziolis GeorgOrthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, 07607, Eisenberg, Germany.
Waldkrankenhaus Rudolf Elle · DEUniversitätsmedizin Göttingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionImplant loosening is the most common indication for revision after total hip arthroplasty and is associated with progressive bone destruction. Contained defects can be treated with impaction bone grafting (IBG). Segmental defects are successfully restored with metal augmentation. Considering the increasing number of hip arthroplasty cases in young patients, it would appear sensible to reconstruct the bone stock for future revisions by biological bone defect reduction. The data on the treatment of segmental defects with IBG without additional stabilization are lacking. MATERIALS AND

methodsPaprosky type IIB defects were milled into 15 porcine hemipelves with segmental defect angles of 40°, 80° and 120°. Contained defects without segmental defects (Paprosky type I) and acetabula without defects served as controls. After IBG, a cemented polyethylene cup (PE) was implanted in each case. Cup migration, rotational stiffness and maximum rupture torque were determined under physiological loading conditions after 2500 cycles.

resultsCompared with the control without defects, IBG cups showed an asymptotic migration of 0.26 mm ± 0.11 mm on average. This seating was not dependent on the size of the defect. The maximum rupture moment was also not dependent on the defect size for cups after IBG. In contrast, the torsional stiffness of cups with an 120° segmental defect angle was significantly lower than in the control group without defects. All other defects did not differ in torsional stiffness from the control without defects.

conclusionsIBG did not show inferior biomechanical properties in segmental type IIB defect angles up to 80°, compared to cups without defects.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisAcetabulumAnimalsBone TransplantationFollow-Up StudiesProsthesis FailureReoperationRetrospective StudiesSwineTreatment OutcomeBiomechanical studyBone defectImpaction bone graftingMigrationRevision total hip arthroplastyTorsional stiffness

Identifiers

PMID34905066
PMCPMC9958163
OpenAlexW4200425404

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.