ArticleRadiology2022

First Clinical Photon-counting Detector CT System: Technical Evaluation.

Kishore Rajendran, Martin Petersilka, André Henning, Elisabeth R Shanblatt, Bernhard Schmidt, Thomas G Flohr, Andrea Ferrero, Francis Baffour, Felix E Diehn, Lifeng Yu and 4 more

Abstract read
In one paragraph

Article in Radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 292 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
292citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

292 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article

232 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

14 authors.

Kishore RajendranFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0002-8314-3642
Martin PetersilkaFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).
André HenningFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).
Elisabeth R ShanblattFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0003-3272-0590
Bernhard SchmidtFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).
Thomas G FlohrFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0002-9524-5531
Andrea FerreroFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).
Francis BaffourFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0001-8005-4823
Felix E DiehnFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0001-9458-8017
Lifeng YuFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0002-4267-1326
Prabhakar RajiahFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0001-7538-385X
Joel G FletcherFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0002-8941-5434
Shuai LengFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0002-6453-9481
Cynthia H McColloughFrom the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (K.R., A.F., F.B., F.E.D., L.Y., P.R., J.G.F., S.L., C.H.M.); Siemens Healthineers, Forchheim, Germany (M.P., A.H., B.S., T.G.F.); and Siemens Medical Solutions, Malvern, Pa (E.R.S.).ORCID 0000-0002-5346-332X

Funding

Comprehensive characterization of coronary atherosclerotic disease using photon-counting-detector dual-source CT and its impact on patient managementR01EB028590 · NIBIB · MAYO CLINIC ROCHESTER · PI LENG, SHUAI, MCCOLLOUGH, CYNTHIA H · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB028590
6 · The paper itself

Abstract

Background The first clinical CT system to use photon-counting detector (PCD) technology has become available for patient care. Purpose To assess the technical performance of the PCD CT system with use of phantoms and representative participant examinations. Materials and Methods Institutional review board approval and written informed consent from four participants were obtained. Technical performance of a dual-source PCD CT system was measured for standard and high-spatial-resolution (HR) collimations. Noise power spectrum, modulation transfer function, section sensitivity profile, iodine CT number accuracy in virtual monoenergetic images (VMIs), and iodine concentration accuracy were measured. Four participants were enrolled (between May 2021 and August 2021) in this prospective study and scanned using similar or lower radiation doses as their respective clinical examinations performed on the same day using energy-integrating detector (EID) CT. Image quality and findings from the participants' PCD CT and EID CT examinations were compared. Results All standard technical performance measures met accreditation and regulatory requirements. Relative to filtered back-projection reconstructions, images from iterative reconstruction had lower noise magnitude but preserved noise power spectrum shape and peak frequency. Maximum in-plane spatial resolutions of 125 and 208 µm were measured for HR and standard PCD CT scans, respectively. Minimum values for section sensitivity profile full width at half maximum measurements were 0.34 mm (0.2-mm nominal section thickness) and 0.64 mm (0.4-mm nominal section thickness) for HR and standard PCD CT scans, respectively. In a 120-kV standard PCD CT scan of a 40-cm phantom, VMI iodine CT numbers had a mean percentage error of 5.7%, and iodine concentration had root mean squared error of 0.5 mg/cm

Indexed as

IodineTomography, X-Ray ComputedHumansPhantoms, ImagingPhotonsProspective StudiesIodine

Identifiers

PMID34904876
PMCPMC8940675

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.